Renishaw FORTiS-S FS Скачать руководство пользователя страница 7

7

www.renishaw.com

Safety function

The FORTiS-S FS encoder system shall provide a safe position when requested by the 
evaluation unit. 

The following restrictions apply to this claim:

• 

The system installer must perform a verified commissioning test during installation.

• 

The system repairer must perform a verified commissioning test following replacement of a 

system part. 

• 

The maximum request rate supported is 32 kHz and 16 kHz for DRIVE-CLiQ.

•  Electrical errors for the BiSS Safety serial interface are detected by the evaluation unit 

comparing CPW and SPW content. See the data sheet 

BiSS Safety for RESOLUTE and 

FORTiS encoders

 (Renishaw part no. L-9517-9884) for more information.

•  Electrical errors for the Siemens DRIVE-CLiQ serial interface are detected by the evaluation 

unit comparing POS1 and POS2 content. See the relevant Siemens AG evaluation unit manual 
for more information.

•  When installed correctly, the FORTiS-S FS encoder system has a mechanical safe position of 

±1 mm.

3.1  Fault exclusions

The following will invalidate the Functional Safety certification of the FORTiS-S FS encoder system:

•  Faults caused by cutting and reconnecting the cable or the use of a non-Renishaw cable that is 

not approved.

•  Incorrect installation.

•  Dismantling.

• 

Operating the system outside the limits specified in this installation guide.

3.2  Failure modes effects and diagnostics analysis

All diagnosed failure modes are detected immediately except for a position discrepancy between 

the two measurement methods which is detected within 375 μs.

See 

section 2

 on page 

5

 for a summary of the FMEDA.

NOTE:

 For the purposes of the FMEDA calculation the following conditions have been assumed: 

 

3.3  Installation

For the safety function to be valid the instructions detailed in this installation guide must be 
followed.

3.4  Commissioning test

The following test MUST be performed when commissioning the FORTiS-S FS encoder system 
and after any repair or maintenance of the system.

Resolution check

Move each readhead by a known distance and confirm that the 

position changes as expected. The tolerance for raising a fault 
condition is relative to the safe position determined by the system 
manufacturer.

Method:

SN29500-2005-1

Environment:

Ground mobile

Temperature:

60 °C

Содержание FORTiS-S FS

Страница 1: ...renishaw www renishaw com fortisdownloads FORTiS S FS enclosed encoder system with multiple readheads Addendum to M 6725 9016 Installation guide M 6725 9188 01 A...

Страница 2: ...2 FORTiS S enclosed encoder system with multiple readheads This page is left intentionally blank...

Страница 3: ...tification 9 5 Summary of EU declaration of conformity 9 6 Summary of UK declaration of conformity 10 7 Overview of the FORTiS S FS encoder system with multiple readheads 10 8 Parts list 11 8 1 Includ...

Страница 4: ...nal Safety data declaration Safety function Certification Summary of EU declaration of conformity Overview of the FORTiS S FS encoder system Parts list Storage and handling Installation drawings Produ...

Страница 5: ...r Siemens DRIVE CLiQ serial interface lS 6 75E 07 lS 9 94E 07 lS 1 32E 06 lS 1 66E 06 Not permitted Not permitted Not permitted lD 1 19E 06 lD 1 73E 06 lD 2 31E 06 lD 2 89E 06 lDD 1 07E 06 lDD 1 56E 0...

Страница 6: ...ance level d Lifetime replacement limits 20 years The FORTiS S FS encoder system provides safe position data that supports the following safety sub functions defined by IEC 61800 5 2 Safe stop 1 SS1 a...

Страница 7: ...validate the Functional Safety certification of the FORTiS S FS encoder system Faults caused by cutting and reconnecting the cable or the use of a non Renishaw cable that is not approved Incorrect ins...

Страница 8: ...y the system manufacturer according to their risk assessment There are no user serviceable parts within the FORTiS S FS encoder system The following maintenance actions are advised Check the extrusion...

Страница 9: ...EU Electromagnetic Compatibility EMC 2011 65 EU On the restriction of the use of certain hazardous substances in electrical and electronic equipment RoHS EN ISO 12100 2010 Safety of machinery General...

Страница 10: ...fer to the FORTiS S FS enclosed encoder system Functional Safety installation guide and safety manual Renishaw part no M 6725 9016 UKD 2021 00819 This declaration of conformity is issued under the sol...

Страница 11: ...urely connecting the encoder cable to the readhead Alignment brackets Two brackets to secure each readhead during transit and set the correct readhead alignment during installation IMPORTANT Retain un...

Страница 12: ...head mounting screws 1 5 mm hex key Air bung removal only if air purge is required 4 mm hex key For locking the mounting aid For use with the M5 extrusion and M5 readhead screw options 5 mm hex key Fo...

Страница 13: ...plications that require multiple readheads traversing a single extrusion the extrusion is fixed with only the readheads moving Please contact your local Renishaw representative if your requirements ar...

Страница 14: ...type A B C Minimum static bend radius Black 137 181 137 15 Green 154 216 154 31 5 Armoured 170 247 170 45 NOTES 1 For required installation information see FORTiS S FS system installation drawings in...

Страница 15: ...1 8 W maximum 75 mA 24 V 24 V as per DRIVE CLiQ specification 24 V power is provided by the DRIVE CLiQ network NOTE Over voltage protection 36 V to 36 V Ripple 200 mVpp maximum frequency up to 500 kHz...

Страница 16: ...t or company names are trade marks of their respective owners Renishaw plc Registered in England and Wales Company no 1106260 Registered office New Mills Wotton under Edge Glos GL12 8JR UK 44 0 1453 5...

Отзывы: