21
QUANTiC RTLC40 /
FASTRACK
installation guide
Power supply
5V −5%/+10%
Typically 150 mA fully terminated (analogue output)
Typically 200 mA fully terminated (digital output)
Power from a 5 Vdc supply complying with the requirements for SELV of standard IEC 60950-1
Ripple
200 mVpp maximum @ frequency up to 500 kHz
Temperature
(system)
Storage
−
20 °C to +70 °C
Operating
0 °C to +70 °C
Humidity
(system)
95% relative humidity (non-condensing) to IEC 60068-2-78
Sealing
IP40
Acceleration
(system)
Operating
400 m/s², 3 axes
Shock
(system)
Operating
500 m/s², 11 ms, ½ sine, 3 axes
Vibration
(readhead)
Operating
100 m/s² max @ 55 Hz to 2000 Hz, 3 axes
(scale)
Operating
300 m/s² max @ 55 Hz to 2000 Hz, 3 axes
Mass
Readhead
9 g
Cable
26 g/m
EMC compliance
IEC 61326-1
Readhead cable
Single-shielded, outside diameter 4.25 ±0.25 mm
Flex life > 20 × 10
6
cycles at 30 mm bend radius
UL recognised component
Maximum length
5 m (analogue)
3 m (digital)
Connector options
Code - connector type
A - 9-way D-type - Digital output only
L - 15-way D-type (standard pin-out) - Analogue output only
D - 15-way D-type (standard pin-out) - Digital output only
H - 15-way D-type (alternative pin-out)
X - 12-way circular connector - Digital output only
J - 14-way JST connector
Typical sub-divisional error (SDE)
Analogue output
Digital output
<
±120 nm
<
±80 nm
CAUTION:
Renishaw encoder systems have been designed to the relevant EMC standards, but must be correctly integrated to achieve EMC compliance.
In particular, attention to shielding arrangements is essential.
General specifications