Step 11.
To remove clamp - after member is fully supported and at rest in a sta-
ble position, relax lifting force, move lock handle to “Open” position,
lift clamp from member
Step 12.
Inspect clamp. Remove from service if in need or repair.
WARNING: In the event the stenciling is worn and not legible or
the tag containing the model, capacity or other pertinent informa-
tion is missing - do not use clamp until it has been properly labeled.
Inspection Kits are available at no charge upon request from the dis-
tributor or RENFROE.
Kit contains: