HE4XRT               

Due to continuing product development, specifications are subject to change without notice.

               © 2012 RenewAire LLC

134775_005                      HE4XRTMan_Jan12.indd                      Revised 01/2012                       www.renewaire.com                      

Page 5

HE4XRT Configuration Chart

6

CORE: "J" = G5

11

WALL TYPE: "S" = SINGLE, "D" = DOUBLE

12

PHASE: "1" = SINGLE-PHASE, "3" = THREE-PHASE

21

22

OPTION 1: 24V TRANSFORMER

25 SAFETY  LISTING (RESTRICTION 15)

MODEL 

NUMBER

MUL

TIPLE-CHOICE OR 

OPTIONAL

 FEA

TURES

ST

ANDARD

FEA

TURES

9

BASE TYPE 
"V", "H", "R", "F"

10 UNUSED IN HE-4X MODELS

13

VOLTAGE: (SEE RESTRICTIONS 2, 3 & 6)

7-8 INDOOR/OUTDOOR: "RT" = ROOFTOP 

1-5 MODEL: "HE-4X"

20

16-17 UNUSED IN HE-4X MODELS

"1" = 115V, "4" = 460V, "5" = 208-230V, "8" = 575V 

24

 "L" = LISTED   "N" = NON-LISTED

OPTION 4: OTHERS

"T" = TR (TRANSFORMER WITH ISOLATION RELAY)

"-" = NONE,

"W" = WHITE PAINT, "C" = CUSTOM PAINT

 "X" = CUSTOM UNIT

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

19

20

21

22

23

24

25

DISCONNECT 

"N" = NON-FUSED (STANDARD)

"F" = FUSED

OPTION 2: FILTER MONITOR 

"-" = NONE,

"F" = FILTER MONITOR BOTH AIRSTREAMS

J

-

- -

T

H E - 4 X R T

15

EA HORSEPOWER

14 FA HORSEPOWER

"V" = 2HP 

"W"= 3HP

"X" = 5HP

RESTRICTION 6 

19 UNIT CONTROL 

"A" = STANDARD UNIT CONTROL WIRING

"V" = ONBOARD VFD BOTH AIRSTREAMS

"F" = ONBOARD VFD FA AIRSTREAM

"E" = ONBOARD VFD EA AIRSTREAM

DAMPERS

"-" = NO DAMPERS (STANDARD)

"D" = DAMPERS BOTH AIRSTREAMS

"E" = DAMPER EA AIRSTREAM

"F" = DAMPER FA/OA AIRSTREAM

18

23 OTHER OPTIONS (RESERVED)

"-" = NONE

RESTRICTIONS:

1: -

2: VOLTAGE CODE "1"  AVAILABLE WITH PHASE CODE 

"1" (SINGLE-PHASE) ONLY.

3: VOLTAGE CODES "4" & "8" AVAILABLE WITH PHASE 

CODE "3" (THREE-PHASE) ONLY.

4:-

5:-

6: VOLTAGE CODES "1"  AVAILABLE ONLY WITH FA/EA 

HORSEPOWER CODE "V".

7: -

8:-

9:-

10:-

11:-

12: -

13:-

14: -

15: SOME UNITS WITH CUSTOM "X" CODE, HE6X & 

HE8X UNITS ARE NOT SAFETY LISTED.  

HE4XRT Dimensions

5 5/8"  Power In

2 1/2"  Control In

55 1/4"  Lifting Lugs

57"

93 7/8"  Overall

Pressure 

Taps (4)

FRONT VIEW

(2)  Ø7/8" holes 

for wiring in 

bottom of E-box

RTH, RTF

ONLY

FA

RA

OA

RA

EA

RTV, RTR

ONLY

RTV, RTF

ONLY

RTH, RTR

ONLY

Disconnect

Switch

FA

79 3/4"  Lifting Lugs

4"

 Top of Curb

5"

80"

20"

82"  Overall

RIGHT VIEW

OA Inlet

Damper

Location

(Optional)

12" X 40"

RA Inlet

(RTH, RTF)

75 7/8"  Control &

Power Wire Inlet

40 1/4"

5 1/2"

38 3/4"

12"

LEFT VIEW

E-box

EA Outlet

12" X 32"

Damper

Location 

(Optional)

12" X 32"

FA Outlet

(RTH, RTR)

17 3/4"

18 5/8"

117 1/4"

Service

Area

14 3/4"

12 1/8"

40 1/8"

Curb Center

68" Service Area

28 3/4"  Curb Center

82"

Unit

RA

(RTV, RTR Only)

11" X 46"

FA

(RTV, RTF Only)

12" X 32"

TOP VIEW

Содержание HE4XRT

Страница 1: ...fficient air is needed for proper combustion and exhausting of gases through the flue chimney of fuel burning equipment that might be installed in the area affected by this equipment If this unit is e...

Страница 2: ...s of unit base into the Roof Curb to secure the unit against high winds On Equipment Rails Review drawing of Roof Curb and specify Equipment Rail to fit Before installing HE4XRT apply roofing and coun...

Страница 3: ...flow measuring stations and manometers in the ductwork connected to the unit These also can be used to determine when filters should be cleaned or changed Use Static Taps in Doors to Measure Airflow R...

Страница 4: ...ide smooth transitions from the ERV s outlets to the duct The ducts connecting to the outlets should be straight for a sufficient distance with gradual transitions to the final duct size These guideli...

Страница 5: ...ARD UNIT CONTROL WIRING V ONBOARD VFD BOTH AIRSTREAMS F ONBOARD VFD FA AIRSTREAM E ONBOARD VFD EA AIRSTREAM DAMPERS NO DAMPERS STANDARD D DAMPERS BOTH AIRSTREAMS E DAMPER EA AIRSTREAM F DAMPER FA OA A...

Страница 6: ...DISCONNECT SWITCH MOTOR STARTER MOTOR STARTER FUSE IF INSTALLED AT FACTORY JUMPER PROVIDED MOTOR EA FACTORY SETTINGS Overload Relay Trip Settings Motor Nameplate FLA Overload Relay Mode Settings Manua...

Страница 7: ...Operation Call for EA Blower Operation OUT 24VAC Class II RELAY TRANSFORMER AND CIRCUIT BREAKER DISCONNECT SWITCH MOTOR STARTER MOTOR STARTER FUSE IF INSTALLED AT FACTORY 24VAC JUMPER PROVIDED FACTORY...

Страница 8: ...the control terminals of this unit 5 Unit is not equipped to receive analog signals such as 1 10vdc or 4 20mA 6 Unit is not equipped to communicate directly with Building Management Systems such as BA...

Страница 9: ...nnect Terminals 2 3 Connect Switch between Terminals 1 4 UNIT INTERNAL CONTROL WIRING SIMPLIFIED A SWITCH OR NON POWERED CONTROL USING UNIT S 24VAC POWER SUPPLY UNIT INTERNAL CONTROL WIRING SIMPLIFIED...

Страница 10: ...1598 2 3350 2 6 2950 2 6 2590 2 3 2175 2 0 1670 1 3210 3 0 2870 2 7 2500 2 4 1742 0 2800 2 9 5 b 1623 4 4165 3 7 3965 3 5 3750 3 3 3475 3 0 3055 2 5 2685 2 3 2290 2 0 1728 2 4240 4 3 4050 4 0 3820 3 7...

Страница 11: ...located on the unit as to give you the most accurate airflow measurement NOTE Do not relocate pressure ports To read SCFM of Fresh Air FA install the high pressure side of your measuring device to the...

Страница 12: ...unds 3 HP BLOWER 4 pounds 5 HP BLOWER 5 pounds GENERAL CLEANING AND INSPECTION Perform general cleaning and inspection when changing filters Remove dust from blower wheels periodically Remove paper le...

Отзывы: