HE4XRT
Due to continuing product development, specifications are subject to change without notice.
© 2012 RenewAire LLC
134775_005 HE4XRTMan_Jan12.indd Revised 01/2012 www.renewaire.com
Page 5
HE4XRT Configuration Chart
6
CORE: "J" = G5
11
WALL TYPE: "S" = SINGLE, "D" = DOUBLE
12
PHASE: "1" = SINGLE-PHASE, "3" = THREE-PHASE
21
22
OPTION 1: 24V TRANSFORMER
25 SAFETY LISTING (RESTRICTION 15)
MODEL
NUMBER
MUL
TIPLE-CHOICE OR
OPTIONAL
FEA
TURES
ST
ANDARD
FEA
TURES
9
BASE TYPE
"V", "H", "R", "F"
10 UNUSED IN HE-4X MODELS
13
VOLTAGE: (SEE RESTRICTIONS 2, 3 & 6)
7-8 INDOOR/OUTDOOR: "RT" = ROOFTOP
1-5 MODEL: "HE-4X"
20
16-17 UNUSED IN HE-4X MODELS
"1" = 115V, "4" = 460V, "5" = 208-230V, "8" = 575V
24
"L" = LISTED "N" = NON-LISTED
OPTION 4: OTHERS
"T" = TR (TRANSFORMER WITH ISOLATION RELAY)
"-" = NONE,
"W" = WHITE PAINT, "C" = CUSTOM PAINT
"X" = CUSTOM UNIT
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
DISCONNECT
"N" = NON-FUSED (STANDARD)
"F" = FUSED
OPTION 2: FILTER MONITOR
"-" = NONE,
"F" = FILTER MONITOR BOTH AIRSTREAMS
J
-
- -
T
H E - 4 X R T
15
EA HORSEPOWER
14 FA HORSEPOWER
"V" = 2HP
"W"= 3HP
"X" = 5HP
RESTRICTION 6
19 UNIT CONTROL
"A" = STANDARD UNIT CONTROL WIRING
"V" = ONBOARD VFD BOTH AIRSTREAMS
"F" = ONBOARD VFD FA AIRSTREAM
"E" = ONBOARD VFD EA AIRSTREAM
DAMPERS
"-" = NO DAMPERS (STANDARD)
"D" = DAMPERS BOTH AIRSTREAMS
"E" = DAMPER EA AIRSTREAM
"F" = DAMPER FA/OA AIRSTREAM
18
23 OTHER OPTIONS (RESERVED)
"-" = NONE
RESTRICTIONS:
1: -
2: VOLTAGE CODE "1" AVAILABLE WITH PHASE CODE
"1" (SINGLE-PHASE) ONLY.
3: VOLTAGE CODES "4" & "8" AVAILABLE WITH PHASE
CODE "3" (THREE-PHASE) ONLY.
4:-
5:-
6: VOLTAGE CODES "1" AVAILABLE ONLY WITH FA/EA
HORSEPOWER CODE "V".
7: -
8:-
9:-
10:-
11:-
12: -
13:-
14: -
15: SOME UNITS WITH CUSTOM "X" CODE, HE6X &
HE8X UNITS ARE NOT SAFETY LISTED.
HE4XRT Dimensions
5 5/8" Power In
2 1/2" Control In
55 1/4" Lifting Lugs
57"
93 7/8" Overall
Pressure
Taps (4)
FRONT VIEW
(2) Ø7/8" holes
for wiring in
bottom of E-box
RTH, RTF
ONLY
FA
RA
OA
RA
EA
RTV, RTR
ONLY
RTV, RTF
ONLY
RTH, RTR
ONLY
Disconnect
Switch
FA
79 3/4" Lifting Lugs
4"
Top of Curb
5"
80"
20"
82" Overall
RIGHT VIEW
OA Inlet
Damper
Location
(Optional)
12" X 40"
RA Inlet
(RTH, RTF)
75 7/8" Control &
Power Wire Inlet
40 1/4"
5 1/2"
38 3/4"
12"
LEFT VIEW
E-box
EA Outlet
12" X 32"
Damper
Location
(Optional)
12" X 32"
FA Outlet
(RTH, RTR)
17 3/4"
18 5/8"
117 1/4"
Service
Area
14 3/4"
12 1/8"
40 1/8"
Curb Center
68" Service Area
28 3/4" Curb Center
82"
Unit
RA
(RTV, RTR Only)
11" X 46"
FA
(RTV, RTF Only)
12" X 32"
TOP VIEW