Applications Engineering
target board’s MCU. Therefore, disconnect the ZDK target from the ICD.
Now click
OK
to update the MMI code. After the MMI update has completed,
reset the ICD by unplugging the USB cable, reconnecting the ICD to the
target board and then reconnecting the USB cable.
5. The FoUSB software should now automatically detect and unlock the target board’s MCU and
display the MCU type without having to select the device. Click
Open
in the left of the FoUSB
program window and browse to the directory in which the demo firmware is stored
(
C:\Renesas\RZB_CC16C_ZDK\Demo).
Select the firmware file ZDK_Demo_Vxx.mot, where
xx is the version number of the code.
6. A popup window displays the ID code of the firmware file you just opened. Click
OK
.
7. Click
Program
in the left of the FoUSB program window.
8. In the Program Flash Window that pops up, make sure “Only Erase Blocks Needed” is checked.
Click
Program
.
It is important that you only erase the blocks needed and
not
the entire Flash
memory, as each ZDK board stores a unique 8-byte MAC address that is factory programmed at
Flash memory address 0xF000. You do not want to erase the MAC address, because the board
will not be able to function without one.
RZB-CC16C-ZDK User’s Manual Rev 1.1
28/ 39
December 2006