2.2 

Connecting User System Interface Cable to User System 

WARNING

 

   

Always switch OFF the user system and the emulator  

  product before the USER SYSTEM INTERFACE CABLE  
  is connected to or removed from any part.  Before connecting,  
  make sure that pin 1 on both sides are correctly aligned.  Failure to  
  do so will damage the user system and the emulator product or will  
  result in PERSONAL INJURY.  The USER PROGRAM will be  
  LOST. 

To connect the cable head to the user system, follow the instructions below. 

 

Содержание TQFP-100G

Страница 1: ...ook over all the business of both companies Therefore although the old company name remains in this document it is a valid Renesas Electronics document We appreciate your understanding Renesas Electronics website http www renesas com April 1st 2010 Renesas Electronics Corporation Issued by Renesas Electronics Corporation http www renesas com Send any inquiries to http www renesas com inquiry ...

Страница 2: ...ct for an application categorized as Specific or for which the product is not intended where you have failed to obtain the prior written consent of Renesas Electronics The quality grade of each Renesas Electronics product is Standard unless otherwise expressly specified in a Renesas Electronics data sheets or data books etc Standard Computers office equipment communications equipment test and meas...

Страница 3: ...H8S 2237Series TQFP 100G User System Interface Cable HS2237ECN61H for E6000 Emulator User s Manual User s Manual ...

Страница 4: ...of bodily injury such as aerospace aeronautics nuclear power combustion control transportation traffic safety equipment or medical equipment for life support 4 Design your application so that the product is used within the ranges guaranteed by Renesas particularly for maximum rating operating supply voltage range heat radiation characteristics installation conditions and other characteristics Rene...

Страница 5: ... original microcomputer H8S 2237 series The HS2237ECN61H is a user system interface cable that connects an H8S 2633 series E6000 emulator HS2633EPI61H hereinafter referred to as the emulator to the IC socket for a TQFP 100G package package code TFP 100G for the H8S 2237 series MCU on the user system ...

Страница 6: ... Installing IC Socket 6 2 2 2 Inserting Cable Head 7 2 2 3 Fastening Cable Head 7 2 2 4 Connecting Cable Body to Cable Head 9 2 3 Recommended Dimensions for User System Mount Pad 10 2 4 Dimensions for User System Interface Cable Head 11 2 5 Resulting Dimensions after Connecting User System Interface Cable 12 Section 3 Installing the MCU to the User System 13 Section 4 Verifying Operation 15 Sectio...

Страница 7: ...N CA Use an NQPACK100SE socket manufactured by Tokyo Eletech Corporation for the TFP 100G package IC socket on the user system Figure 1 shows the configuration of the HS2237ECN61H user system interface cable for the TFP 100G package ...

Страница 8: ...To emulator station Cable body Screws M2 x 6 mm Socket cover User system IC socket Cable head Screws M2 x 10 mm for fastening cable head Figure 1 HS2237ECN61H User System Interface Cable 2 ...

Страница 9: ...udes flat cable 2 Cable head 1 3 IC socket 1 For the TFP 100G package 4 Socket cover 1 For installing a TFP 100G packaged MCU 5 Screws M2 x 10 mm 4 For fastening cable head 6 Screws M2 x 6 mm 4 For installing a TFP 100G packaged MCU 7 Guide pins φ 1 mm 3 For determining the IC socket location 8 Screwdriver 1 For tightening screws 9 Documentation 1 User s manual for HS2237ECN61H this manual ...

Страница 10: ... connecting make sure that pin 1 on both sides are correctly aligned Failure to do so will damage the user system and the emulator product or will result in PERSONAL INJURY The USER PROGRAM will be LOST To connect the cable body to the emulator station make sure the user system and emulator station are turned off 6 0 0 0 Emulator station E Cable body User system interface cable Figure 2 Connecting...

Страница 11: ...TEM INTERFACE CABLE is connected to or removed from any part Before connecting make sure that pin 1 on both sides are correctly aligned Failure to do so will damage the user system and the emulator product or will result in PERSONAL INJURY The USER PROGRAM will be LOST To connect the cable head to the user system follow the instructions below 5 ...

Страница 12: ...o determine where to install the IC socket as shown in figure 3 User system IC socket NQPACK100SE manufactured by Tokyo Eletech Corporation Guide pins 4 projections to apply epoxy resin adhesive to Bottom view of IC socket Pin 1 Figure 3 Location Setting of IC Socket 2 Solder the IC socket for a TFP 100G package to the user system CAUTION Be sure to completely solder the leads so that the solder s...

Страница 13: ...e inserting 2 Use the screwdriver provided for tightening screws 3 The tightening torque must be 0 054 N m or less If the applied torque cannot be accurately measured stop tightening when the force required to turn the screw becomes significantly greater than that needed when first tightening If a screw is tightened too much the screw head may break or an IC socket contact error may be caused by a...

Страница 14: ...ernating between screws on opposing corners Take special care such as manually securing the IC socket soldered area to prevent the soldered IC socket from being damaged by overtightening the screws or twisting the components Pin 1 Cable head IC socket NQPACK100SE manufactured by Tokyo Eletech Coporation Screws M2 x 10 mm User system Figure 4 Connecting User System Interface Cable to User System 8 ...

Страница 15: ...2 2 4 Connecting Cable Body to Cable Head Cable body Cable head Remove jig Push the remove jig Removing User system Connect the cable body to the cable head Figure 5 Fastening Cable Body 9 ...

Страница 16: ...with an IC socket for an TFP 100G package NQPACK100SE manufactured by Tokyo Eletech Corporation Note that the dimensions in figure 6 are somewhat different from those of the actual chip s mount pad Unit mm 0 40 0 05 0 20 0 05 0 40 x 24 9 60 0 05 0 40 x 24 9 60 0 05 11 10 max 15 10 min 0 40 0 05 Figure 6 Recommended Dimensions for Mount Pad 10 ...

Страница 17: ...mensions for User System Interface Cable Head The dimensions for the user system interface cable head are shown in figure 7 Unit mm Tolerance 0 5 mm Figure 7 Dimensions for User System Interface Cable Head 11 ...

Страница 18: ...sions after connecting the user system interface cable head to the user system are shown in figure 8 Cable head User system Unit mm Tolerance 0 5 mm IC socket NQPACK100SE manufactured by Tokyo Eletech Corporation Figure 8 Resulting Dimensions after Connecting User System Interface Cable 12 ...

Страница 19: ...e screw head may break or an IC socket contact error may be caused by a crack in the IC socket solder 4 If the MCU does not operate correctly cracks might have occurred in the solder Check conduction with a tester and re solder the IC socket if necessary Check the location of pin 1 before inserting the MCU into the IC socket on the user system as shown in figure 9 After inserting the MCU fasten th...

Страница 20: ...MCU Pin 1 IC socket NQPACK100SE manufactured by Tokyo Eleteck Corporation User system Screws M2 x 6 mm Socket cover Figure 9 Installing MCU to User System 14 ...

Страница 21: ...ls refer to the Emulator Supplementary Information HS2633EPI61HE To use the emulator internal clock Select the clock in the emulator station as the system clock φ by using the CLOCK command emulator command To use the external clock on the user system Supply the external clock from the user system to the emulator Connect a crystal oscillator to the EXTAL and XTAL terminals for the system clock φ a...

Страница 22: ...etal objects on the user system interface cable 5 While the emulator station is connected to the user system with the user system interface cable force must not be applied to the cable head Place the emulator station user system interface cable and user system as shown in the example in figure 11 User system Cable Emulator station Place components so that the cable body and cable head are parallel...