UM-B-041
SmartBond Production Line Tool
User Manual
Revision 4.8
02-Nov-2022
CFR0012
77 of 170
© 2022 Renesas Electronics
Option
Description
Instrument
Select the Temperature measurement DLL. Names are shown only if a Temperature
measurement instrument DLL exists in the project folder
temp_meas_instr_plugins
.
Interface
The interface of the instrument to be used by the driver.
7.2.6.13
Scan Test
Figure 64: Scan Test
describes the available options for the
Scan Test
.
By enabling this test, the Golden Unit will scan for the DUT
’s BD addresses advertised after the
customer firmware has been programmed to the DUT. For this test to work, a bootable firmware with
the ability to advertise with the BD address given by the PLT must be burned into each DUT.
Additionally, the BD addresses provided by the PLT should be burned into OTP CS memory such
that the devices advertise with the BD addresses the tool uses.
Table 50: Scan Test Options
Option
Description
Enable
This option enables the Scan test.
Scan retries
The total number of Bluetooth
®
LE advertising scans the Golden Unit will perform.
DUT reboot
Define after how many retries the PLT will reboot the DUTs.
DUT reboot
difference
Set the time difference between each DUT when the PLT reboots the devices, in
order to avoid air collisions.
DUT reboot time
The time the VBAT will remain low during the device reboot. This value is time in