Table 4: Jumpers
Jumper
PLT HW
version
Description
J26
A, B, C, D
Connects the VBAT line from the PLT power supply to the DUTs. This jumper can be
used when there is no multi-meter instrument connected for current measurement.
J37
B, C, D
This jumper sets the Golden Unit’s SPI Flash chip select (CS) pin to high. This
jumper is placed when the Golden Unit should
NOT
boot from the SPI flash.
J42
B, C, D
Feeds the VPP lines of the DUT connectors with VPP voltage used for OTP burning
in DA14580/1/2/3 DUTs.
J46
C, D
This jumper can be used to reset the Golden Unit. The two pins on the jumper are the
same as the ones in the GU reset switch next to the jumper.
J47
D
This
jumper connects the Golden Unit’s FTDI DTR line to the Golden Unit’s reset pin.
With this jumper on the PLT, software can reset the Golden Unit on-demand.
5.8.1
J26 - Current Measurements
As shown in
jumper J26 should be mounted when no external current meter is attached.
Otherwise, when a current meter is connected via the blue banana sockets to measure the device
current, the J26 jumper should be removed.
Figure 12: C
onnections for ‘Floating Current’ Measurements
5.8.2
J47, J46 - GU Reset
For a GU hardware reset, jumper J47 should be mounted and jumper J46 should be removed. These
two jumpers are involved in the circuit illustrated in
. In this way, the PLT software will
control the GU hardware reset.
shows the jumper placement on the actual PCB.
Figure 13: Location of J46 Jumper