background image

( 27 / 52 )

(2) Connecting the Cable to the Emulation Pod

Figure 3.10 shows how to connect the FLX120-RPD and the emulation pod.

Figure 3.10 Connecting FLX120-RPD and emulation pod

CAUTION

Note on Connecting the Cable:

• Always shut OFF power before connecting the cable. The power ON state could

destroy internal circuits.

Note on Securing the Screws:

• After connecting the cable to the emulator main unit, be sure to secure the screws.

Содержание Single-Chip Microcomputer M37900T2-RPD-E

Страница 1: ...M37900T2 RPD E Emulation Pod for 7900 Series MCUs User s Manual Rev 1 00 July 1 2003 REJ10J0191 0100Z ...

Страница 2: ...contained herein for any specific purposes such as apparatus or systems for transportation vehicular medical aerospace nuclear or undersea repeater use The prior written approval of Renesas Technology Corporation and Renesas Solutions Corporation is necessary to reprint or reproduce in whole or in part these materials If these products or technologies are subject to the Japanese export control res...

Страница 3: ...uct are shown in 2 2 Package Components page 15 of this user s manual If there is any question or doubt about this product contact your local distributor To use the product properly Precautions for Safety In both this user s manual and on the product itself several icons are used to insure proper handling of this product and also to prevent injuries to you or other persons or damage to your proper...

Страница 4: ...ircuit Boards 23 3 2 Connecting the Pod Probe and Emulation Pod 24 3 3 Connecting the PC4701 and Emulation Pod 26 1 Connecting the Cable to the PC4701 26 2 Connecting the Cable to the Emulation Pod 27 Chapter 4 Usage 29 4 1 Turning on Power 30 1 Checking the Connection of the System 30 2 Turning on Power 30 3 LED Display When PC4701 Starts Up Normally 31 4 2 Downloading Firmware 32 1 When It is Ne...

Страница 5: ... the LED Display of the PC4701 is Abnormal 43 2 Errors Occur at Debugger Startup target connected 44 3 Errors Occur at Debugger Startup target not connected 45 6 3 Operation Differs from that of MCUs with Flash Memory 46 1 Initializing the Internal Resources of an MCU at Power on 46 2 Oscillator Circuits 46 Chapter 7 Maintenance and Guarantee 47 7 1 Maintenance 48 7 2 Guarantee 48 7 3 Repair Provi...

Страница 6: ... 6 52 MEMO ...

Страница 7: ...d Meanings 8 Warning for Installation 9 Warnings for Use Environment 9 Caution to Be Taken for Modifying This Product 9 Cautions to Be Taken for This Product 9 Cautions to Be Taken for Turning On the Power 9 Note on Malfunctions in the PC4701 System 10 Notes on Downloading Firmware 10 Notes on the Self check 10 Note on Quitting the Emulator Debugger 10 Note on Final Evaluation 10 Notes on Power Su...

Страница 8: ...ings The following pages describe the symbols WARNING CAUTION and IMPORTANT In addition to the three above the following are also used as appropriate means WARNING or CAUTION Example CAUTION AGAINST AN ELECTRIC SHOCK means PROHIBITION Example DISASSEMBLY PROHIBITED means A FORCIBLE ACTION Example UNPLUG THE POWER CABLE FROM THE RECEPTACLE If the requirements shown in the WARNING sentences are igno...

Страница 9: ...f the emulator main unit and the target MCU connector pins directly Static electricity may damage the internal circuits Do not pull the emulation pod main unit by the flexible cable FLX120 RPD for connecting to the emulator main unit or the flexible cable FLX100 for connecting the target system The cable may cause a break Flexible cable FLX120 RPD for connecting to the emulator main unit and the f...

Страница 10: ...ownloading the firmware If this happens the product will not start up properly If power is shut off unexpectedly redownload the firmware in maintenance mode Be sure to disconnect the target system before downloading the firmware IMPORTANT Note on Malfunctions in the PC4701 System If the emulator malfunctions because of interference like external noise do the following to remedy the trouble 1 Press...

Страница 11: ...the internal flash ROM capacity of the selected MCU Example For MCUs with 512KB flash ROM Emulation memory size 768 KB 256 KB is used as work area 256 KB of emulation memory in banks 0 to 3 cannot be allocated 3 ROM Address Disable the allocated emulation memory against writes by the user program RAMs that have been mapped to external locations cannot be disabled against writes 4 DMA Address In th...

Страница 12: ... 12 52 MEMO ...

Страница 13: ...tion and the preparation for using this product for the first time 2 1 Terminology 14 2 2 Package Components 15 2 3 Other Tool Products Required for Development 15 2 4 Name of Each Part 16 1 System Configuration 16 2 Inside of the Emulation Pod 17 2 5 When Using the Emulator for the First Time 18 ...

Страница 14: ...ted to the emulation pod M37900T2 RPD E and emulates the target MCU Emulator debugger M3T PD79 This means a software tool M3T PD79 to control the emulator from the host machine through an interface Firmware Program that analyzes contents of communication with the emulator debugger and controls the emulator hardware This program is installed in the EEPROM This program is downloadable from the emula...

Страница 15: ...ard programs development on the 7900 Series MCUs the products listed below are necessary in addition to those contained package above Get them separately To purchase these products contact your nearest distributer Emulator main unit Emulator debugger Pod probe Converter board PC4701 M3T PD79 V 2 10 or greater is recommended M379xxTx PRB xx varies with MCU Pod probe which matches to the MCU group i...

Страница 16: ...lation pod for 7900 Series MCUs By replacing the pod probe on the tip of this product it matches to the MCU dependent part of 7900 Series MCUs 2 Pod probe M379xxTx PRB This is an MCU dependent part which matches to the 7900 Series MCU group option 3 Converter board This is a connector board which matches to the MCU package option ...

Страница 17: ...rd Board on which the 1 MB 256 KB emulation memory is mounted 3 Oscillator circuit board Xin 20 MHz and Xcin 32 kHz when shipped from factory Board on which the internal oscillator circuit of the emulation pod is mounted Operating frequency can be changed by replacing this board with other available oscillator circuit boards 4 Interface board Board which is connected to the pod probe ...

Страница 18: ... PC4701 Figure 2 3 Firmware download procedure when emulator is used for the first time To make sure the emulation pod works properly run the self check For self check procedures see 4 4 Self check page 34 Shut power OFF Connect the PC4701 and this product Within 2 seconds of turning the power ON press the RESET switch of the PC4701 and check maintenance mode is accessed Download the firmware usin...

Страница 19: ...ecting Clock Supply 20 1 Using the Oscillator Circuit on the Target System 21 2 Changing the Internal Oscillator Circuit of the Emulation Pod 22 3 Replacing the Oscillator Circuit Board 23 3 2 Connecting the Pod Probe and Emulation Pod 24 3 3 Connecting the PC4701 and Emulation Pod 26 1 Connecting the Cable to the PC4701 26 2 Connecting the Cable to the Emulation Pod 27 ...

Страница 20: ...able 3 1 lists the factory settings of each clock supply Table 3 1 Clock supply to the MCU IMPORTANT Note on Changing the Clock Supply The clock supply can be set by the Init dialog box when starting up the emulator debugger or inputting CLK command on the script window Clock Description Display of emulator debugger Factory setting XIN J2 side Internal oscillator circuit of emulation pod OSC 3 20 ...

Страница 21: ...ulation pod with an external clock construct the oscillator circuit as shown in Figure 3 1 in the target system and input the oscillator output at 50 duty within the operating range of the evaluation MCU into the XIN pin And the XOUT pin should be open Make note of the fact that in the oscillator circuit shown in Figure 3 2 where a resonator is connected between the XIN and XOUT pins oscillation d...

Страница 22: ... of the OSC 2 oscillator circuit board bare board and where connector pins are located Figure 3 4 shows the circuitry of the OSC 2 oscillator circuit board bare board Use the number of oscillator circuits recommended by the oscillator manufacturer Figure 3 3 External view of the oscillator board OSC 2 and connector pin assignment J1 4 GND Figure 3 4 Circuit of the oscillator board OSC 2 J1 3 Oscil...

Страница 23: ...w connecting the oscillator board 3 Lift off the oscillator board 4 Insert the connector J1 of the oscillator board to the connector J1 or J2 of the interface board M37900T PRT 5 Fix the oscillator circuit board to the M37900T PRT board with the screw 6 Replace the upper cover and secure the four screws Figure 3 6 Replacing oscillator boards Figure 3 5 Removing the upper cover CAUTION When Removin...

Страница 24: ...M37900T2 RPD E 2 Pod probe M379xxTx PRB designed for each MCU group Figure 3 7 Connecting pod probe 1 Unscrew the 4 screws of the M379xxTx PRB 2 Connect the connectors J3 J4 of the M379xxTx PRB and connectors J1 J2 of the M379xxTx PRBM to the connectors J3 J4 of the M37900T2 RPD E s FLX100 and connectors J5 J6 of the M379xxTx PRB respectively 3 Fix the M379xxTx PRB with 4 screws ...

Страница 25: ...PRBM 1 Unscrew the 4 screws of the M379xxTx PRB 2 Remove the M379xxTx PRBM from the M379xxTx PRB In this time lift off the M379xxTx PRBM horizontally Otherwise the connector may cause a break CAUTION When Connecting Pod Probe Always shut OFF power when connecting the pod probe The power ON state could destroy internal circuits The insertion removal iterations of the connector of the pod probe are ...

Страница 26: ...connector of the PC4701 then secure with the screws 1 Connecting the Cable to the PC4701 Figure 3 9 shows how to connect the PC4701 and FLX120 RPD Figure 3 9 Connecting PC4701 and FLX120 RPD CAUTION Note on Connecting the Cable Always shut OFF power before connecting the cable The power ON state could destroy internal circuits Note on Securing the Screws After connecting the cable to the emulator ...

Страница 27: ...ulation pod Figure 3 10 Connecting FLX120 RPD and emulation pod CAUTION Note on Connecting the Cable Always shut OFF power before connecting the cable The power ON state could destroy internal circuits Note on Securing the Screws After connecting the cable to the emulator main unit be sure to secure the screws ...

Страница 28: ... 28 52 MEMO ...

Страница 29: ...ay When PC4701 Starts Up Normally 31 4 2 Downloading Firmware 32 1 When It is Necessary to Download Firmware 32 2 Downloading Firmware in Maintenance Mode 32 4 3 Starting up the Emulator Debugger Setting EMEM Dialog 33 1 Processor Mode 33 2 Emem Address 33 3 ROM Address 33 4 DMA Address 33 5 8 bit bus mode Address 33 6 Map Address 33 4 4 Self check 34 1 Self check Procedure 34 2 If an Error is Det...

Страница 30: ...The emulator s VCC pin is connected to the target system in order to monitor target system voltage For this reason the emulator cannot supply power to the target system Therefore provide the target system with a separate power supply from that of the emulator Keep target system power supply voltage within the MCU s specified range and suit to the emulator MCUs as shown below 1 For 5 0V version MCU...

Страница 31: ...e power turned on IMPORTANT Note on Memory Expansion Mode and Microprocessor Mode To use memory expansion or microprocessor mode be sure to set the RDY and HOLD pins so that they are not active at startup Otherwise the emulator system will not start up correctly If this does not light check the voltage of the target system Check that power is supplied to all the terminals This does not light when ...

Страница 32: ... RESET switch on the emulator front panel This will switch the emulator to maintenance mode 2 Start up the emulator debugger When the Init dialog box setup is complete the dialog which urges to download the firmware will appear Download the firmware following messages Required time for downloading the firmware depends on the connection of the interface For USB and LPT parallel interface About 20 s...

Страница 33: ...omatically allocated as a work area for spaces corresponding to flash ROM Therefore the usable emulation memory size varies with the internal flash ROM capacity of the selected MCU Example For MCUs with 512KB flash ROM Emulation memory size 768 KB 256 KB is used as work area 256 KB of emulation memory in banks 0 to 3 cannot be allocated 3 ROM Address Disable the allocated emulation memory against ...

Страница 34: ...tory setting refer to the user s manual of the pod probe 2 When the target system is connected disconnect the target system 3 Within 2 seconds of activating power to the emulator press the RESET switch on the emulator front panel to switch the emulator to maintenance mode 4 Check the SAFE LED starts blinking and then press the RESET switch again 5 The self check will start If the normal result is ...

Страница 35: ... Detected in the Self check If the self check does not result normally ERROR 1 and ERROR 2 in Figure 4 3 check the following Check the connection of the emulation pod and the PC4701 Check the connection of the emulation pod and the pod probe Redownload the proper firmware Check if the switches in the pod probe are set same as the factory setting refer to the user s manual of the pod probe ...

Страница 36: ... 36 52 MEMO ...

Страница 37: ... 37 52 Chapter 5 Specifications This chapter describes specifications of this product 5 1 Specifications 38 5 2 External Dimensions of the Emulation Pod 39 ...

Страница 38: ...e temperature Power supply to emulation pod Overseas standards PC4701 7900 Series pod probe M379xxTx PRB Fixed 256 KB Fixed 00 to 03 banks attribute specifiable Changeable 1 MB Possible to allocate by bank attribute specifiable Internal oscillator circuit board switchable to external oscillator 5 to 35 C no dew 10 to 60 C no dew Supplied from emulator main unit 1 U S EMI standards FCC part 15 Clas...

Страница 39: ... 39 52 Figure 5 1 External dimensions of the emulation pod 5 2 External Dimensions of the Emulation Pod Unit mm ...

Страница 40: ... 40 52 MEMO ...

Страница 41: ... the Emulator Debugger Does Not Start Up Properly 43 1 When the LED Display of the PC4701 is Abnormal 43 2 Errors Occur at Debugger Startup target connected 44 3 Errors Occur at Debugger Startup target not connected 45 6 3 Operation Differs from that of MCUs with Flash Memory 46 1 Initializing the Internal Resources of an MCU at Power on 46 2 Oscillator Circuits 46 ...

Страница 42: ...ayed Display normal Turning on the power of the PC4701 Program window of emulator debugger displayed Front panel LED status of the PC4701 Init dialog box of emulator debugger displayed 1 Check emulator system connections See 3 3 Connecting the PC4701 and Emulation Pod page 26 2 Redownload the firmware See 4 2 Downloading Firmware page 32 3 Restart the PC4701 system EMEM dialog box of emulator debu...

Страница 43: ...n Pod page 26 2 Check the proper firmware is downloaded 3 Check the clocks of the emulator debugger are not set to EXT SeetheCLKcommandoftheemulatordebugger 4 Check the oscillation circuit in the emulation pod is oscillating See 3 1 Selecting Clock Supply page 20 1 Recheck the connection between the PC4701 this product and pod probe See the user s manual of the pod probe See 3 3ConnectingthePC4701...

Страница 44: ...of the target system is pulled up 2 Check the reset pin of the target system has changed from L to H level 1 Check the NMI pin is H level 2 When in memory expansion or microprocessor mode check the RDY and HOLD pins are H level respectively 3 If the reset circuit of the target system has a watchdog timer disable the timer 4 Check power is properly supplied to the target system and that the target ...

Страница 45: ... page 32 2 Recheck the connection between the PC4701 this product and pod probe See the user s manual of the pod probe See 3 3 Connecting the PC4701 and Emulation Pod page 26 Download the proper firmware See 4 2 Downloading Firmware page 32 1 The program may be uncontrollable in areas memory not allocated Recheck the map setting See 4 3 Starting up the Emulator Debugger Setting EMEM Dialog page 33...

Страница 46: ... are initialized when starting up the emulator Therefore the operation differs from that of actual MCUs 2 Oscillator Circuits Make note of the fact that in the oscillator circuit where a resonator is connected between the XIN and XOUT pins oscillation does not occur because a flexible cable buffer IC and other devices are used between the evaluation MCU and the target system ...

Страница 47: ...er 7 Maintenance and Guarantee This chapter describes how to maintenance repair provisions and how to request for repair 7 1 Maintenance 48 7 2 Guarantee 48 7 3 Repair Provisions 48 7 4 How to Request for Repair 49 ...

Страница 48: ...the leasing company or the owner 7 3 Repair Provisions 1 Repair with extra charge The products elapsed more than one year after purchase can be repaired with extra charge 2 Replacement with extra charge If your product s fault falls in any of the following categories the fault will be corrected by replacing the entire product instead of repair or you will be advised to purchase new one depending o...

Страница 49: ...e Repair Request Sheet to Renesas Solutions Corp Renesas Solutions When the faulty product is repaired it will be returned to the customer at the earliest convenience CAUTION Note on Transporting the Product When sending your product for repair use the packing box and cushion material supplied with this product when delivered to you and specify handling caution for it to be handled as precision eq...

Страница 50: ... 50 52 MEMO ...

Страница 51: ...M37900T2 RPD E User s Manual Rev 1 00 July 1 2003 REJ10J0191 0100Z COPYRIGHT 2003 RENESAS TECHNOLOGY CORPORATION AND RENESAS SOLUTIONS CORPORATION ALL RIGHTS RESERVED ...

Страница 52: ......

Отзывы: