Chapter 3. Setting Up
To use this emulation pod with your application system, it is necessary to set as follows. Set the
following after removing the upper cover.
3.1 Selecting Clock Supply
There are two ways to supply a clock to the MCU, using the oscillator circuit of the emulation pod
or using the oscillator circuit on the target system. Table 3.1 lists the factory-settings of each clock
supply.
Table 3.1 Clock supply to the MCU
IMPORTANT
Note on Changing the Clock Supply:
• The clock supply can be set by the Init dialog box when starting up the emulator
debugger or inputting CLK command on the script window.
Clock
Description
Display of emulator debugger Factory-setting
X
IN
(J2 side)
Internal oscillator circuit of emulation pod
(OSC-3: 20 MHz)
Target system
Internal
External
Yes
-
X
CIN
(J1 side)
Internal oscillator circuit of emulation pod
(OSC-3: 32 kHz)
Target system
Internal
External
Yes
-