R01UH0822EJ0100 Rev.1.00
Page 364 of 1041
Jul 31, 2019
RX13T Group
19. Multi-Function Timer Pulse Unit 3 (MTU3c)
Note:
The initial output value of negative-phase waveform changes to an active level after the dead time has passed since counting
starts.
shows an example of output in complementary PWM mode (one phase) when OLSN = 1 and OLSP = 1.
Figure 19.2
Example of Output in Complementary PWM Mode
Table 19.30
Output Level Select Function
Bit 0
Function
OLSP
Initial Output
Active Level
Compare Match Output
Up-Counting
Down-Counting
0
High level
Low level
Low level
High level
1
Low level
High level
High level
Low level
Table 19.31
Output Level Select Function
Bit 1
Function
OLSN
Initial Output
Active Level
Compare Match Output
Up-Counting
Down-Counting
0
High level
Low level
High level
Low level
1
Low level
High level
Low level
High level
MTU3.TCNT and MTU4.TCNT values
MTU3.TGRA
MTU4.TGRA
TDDR
0000h
Time
MTU4.TCNT
MTU3.TCNT
Positive-
phase
output
Negative-
phase
output
Active level
Compare match
output (up-count)
Initial
output
Initial
output
Compare match output
(down-count)
Compare match
output (up-count)
Compare match output
(down-count)
Active level
Active
level