4.3  Shutdown the Power Supply 

(1)  Shut down user system power 

Shut down the power supply of the user system.

 

(2) 

Shut down the power supply of the emulator 

Disconnect the USB cable between the host machine and the E2 Emulator to turn off the E2 Emulator 

power. 

 

5.  Jumper Pins (JP1 - JP6) Settings 

The jumper pin settings differ depending on the software used. If you are using the debugger (e2studio), see 

Section 5.1. If you are using the Renesas Flash Programmer, see Section 5.2. 
 

5.1  Settings when using the debugger (e

2

studio) 

Set the jumper pins (JP1 - JP6) of this product according to the settings of the debugger (e2studio). 
When the setting of (2) in Figure 5.1 is 

JTAG

, set the jumper pins (JP1 - JP6) of this product according to 

JTAG

 in Table 5.1.  

When the setting of (2) in Figure 5.1 is 

SWD

, set the jumper pin (JP1 - JP6) of this product according to the 

SWD

 in Table 5.1. 

 

(1)

(3)

(2)

Set the debugger (e2studio) as follows.

(1) Debug hardware: Set according to the type of emulator.

     E2 (ARM) / E2 Lite (ARM)

(2) Type: Set according to the communication I/F.

               JTAG / SWD

     Speed (kHz): AUTO

(3) Power Target From The Emulator (MAX 200mA): Yes

     Power Target via: User Interface     

     Supply voltage (V): 3.3

 

Figure 5.1 Debugger (e

2

 studio) settings 

 

Table 5.1 Jumper pin (JP1 - JP6) settings when using the debugger (e

2

 studio) 

JTAG 

SWD 

 

JP1

JP2

JP3

JP4

JP5

JP6

1

2

3

1

2

3

1

2

3

1

2

3

1

2

3

1

2

3

 

JP1, JP6: 

1-2 (TMS) 

JP2, JP4: 
  1-2 (RA) 
JP3, JP5: 
  1-2 (DEBUG) 

 

 

JP1

JP2

JP3

JP4

JP5

JP6

1

2

3

1

2

3

1

2

3

1

2

3

1

2

3

1

2

3

 

JP1, JP6: 

2-3 (SWDIO) 

JP2, JP4: 
  1-2 (RA) 
JP3, JP5: 
  1-2 (DEBUG) 

 

 
 

 

Содержание RTE0T00020KCAA0000J

Страница 1: ... across the isolation barrier but then the circuitry on both sides of the barrier must be regarded as operating at an unsafe voltage and further isolation insulation systems must form a barrier between these circuits and any user accessible circuitry according to safety standard requirements Caution to Be Taken for Disposal Penalties may be applicable for incorrect disposal of this waste in accord...

Страница 2: ...ply of the user system promptly when you disconnect the user system from the emulator debugger If the power supply of a user system continues being ON a user program will carry out a reset start Moreover you may fail to reconnect the emulator debugger to the user system When an attempt to reconnect to the user system has failed turn off the user system and then unplug and plug the USB cable of the...

Страница 3: ...r Lite Set the jumper pins according to the usage before connecting See Chapter 5 4 1 Setup Make sure that the user system and emulator are powered off before installing Do not connect the USB cable to the emulator Connect the emulator to the J1 connector E2 of this product using the user interface cable Connect the user system and the J2 connector Target of this product with the user interface ca...

Страница 4: ...er e2studio When the setting of 2 in Figure 5 1 is JTAG set the jumper pins JP1 JP6 of this product according to JTAG in Table 5 1 When the setting of 2 in Figure 5 1 is SWD set the jumper pin JP1 JP6 of this product according to the SWD in Table 5 1 1 3 2 Set the debugger e2studio as follows 1 Debug hardware Set according to the type of emulator E2 ARM E2 Lite ARM 2 Type Set according to the comm...

Страница 5: ... according to RE in Table 5 2 Set Power Supply to 3 3V from Tool Details dialog box on the Connect Settings tab Location of 1 in Microcontroller For Ax select RA settings at Jumper Pins In the above example set the jumper pin to RA with A4 For 0E select RE settings at Jumper Pins 1 Figure 5 2 Configuring Renesas Flash Programmer Table 5 2 Jumper Pins JP1 JP6 Settings for Renesas Flash Programmer R...

Страница 6: ...RTE0T00020KCAA0000J User s Manual R20UT5065EJ0100 Rev 1 00 Page 6 of 8 Dec 2021 6 External Dimensions Figure 6 1 External Dimensions 50 mm 40 mm ...

Страница 7: ... equipment Its use outside the laboratory classroom study area or similar such area invalidates conformity with the protection requirements of the Electromagnetic Compatibility Directive and could lead to prosecution The product generates uses and can radiate radio frequency energy and may cause harmful interference to radio communications However there is no guarantee that interference will not o...

Страница 8: ...D ALL WARRANTIES EXPRESS OR IMPLIED WITH RESPECT TO THIS DOCUMENT AND ANY RELATED OR ACCOMPANYING SOFTWARE OR HARDWARE INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE 8 When using Renesas Electronics products refer to the latest product information data sheets user s manuals application notes General Notes for Handling and Using Semiconduc...