background image

RTE0T00020KCAA0000J 

User's Manual

 

R20UT5065EJ0100  Rev.1.00 

 

Page 3 of 8 

Dec 2021 

 

3.  Notes on Usage 

Note on Power-Supply Voltage: 

 

When you use an emulator with this isolator connected, power-supply voltage of the MCU on your 

system should be between 3.0 V and 5.5 V. Power-supply voltage less than 3.0 V is not supported 

Power-supply voltage less than 3.0 V is not supported. 

Note on Signal Delay: 

 

When this product is connected, the communication interface speed may be limited due to the signal 

delay of the isolation circuit. 

Use the e

2

studio as the debugger. 

Set the e

2

studio communication speed to "AUTO". (The connection speed is optimal.) 

The e

2

studio must be version 2021-10 (21.10.0) or higher. 

Note on Programming Software: 

 

Use the Renesas Flash Programmer as the writing software. 

If you are unable to start the Renesas Flash Programmer, run e

2

studio once. 

 

4.  Usage 

Sections 4.1 to 4.3 of this chapter use the E2 Emulator as an example. If you are using the E2 emulator Lite, 

read "E2 Emulator" as "E2 emulator Lite". Set the jumper pins according to the usage before connecting. 

(See Chapter 5) 

4.1  Setup 

Make sure that the user system and emulator are powered off before installing. Do not connect the USB 

cable to the emulator.  
Connect the emulator to the J1 connector (E2) of this product using the user interface cable. 
Connect the user system and the J2 connector (Target) of this product with the user interface cable. 
 

RTE0T00020KCAA0000J

USB cable

Host machine

User system

User interface cable

 

Figure 4.1 RTE0T00020KCAA0000J Installation Method 

 

4.2  Starting the Power Supply 

Start the power supply following the procedure below. 

(1) 

Starting the emulator power supply 

Connect the USB cable between the host machine and the E2 Emulator. E2 Emulator power is 

supplied. 

(2) 

User System Power Up 

User System Power Up Power is supplied to this product from the J2-1 terminal. 

(3) 

Debugger startup (power supply setting)  

Start the debugger from the control PC, and set the power supply to the target device to ON in the 

initial setting screen. Select 3.3V for supply voltage regardless of the voltage used for the user 

system. 

Refer to the user's manual for your emulator (E2 Emulator or E2 emulator Lite) for the following settings. 

Содержание RTE0T00020KCAA0000J

Страница 1: ... across the isolation barrier but then the circuitry on both sides of the barrier must be regarded as operating at an unsafe voltage and further isolation insulation systems must form a barrier between these circuits and any user accessible circuitry according to safety standard requirements Caution to Be Taken for Disposal Penalties may be applicable for incorrect disposal of this waste in accord...

Страница 2: ...ply of the user system promptly when you disconnect the user system from the emulator debugger If the power supply of a user system continues being ON a user program will carry out a reset start Moreover you may fail to reconnect the emulator debugger to the user system When an attempt to reconnect to the user system has failed turn off the user system and then unplug and plug the USB cable of the...

Страница 3: ...r Lite Set the jumper pins according to the usage before connecting See Chapter 5 4 1 Setup Make sure that the user system and emulator are powered off before installing Do not connect the USB cable to the emulator Connect the emulator to the J1 connector E2 of this product using the user interface cable Connect the user system and the J2 connector Target of this product with the user interface ca...

Страница 4: ...er e2studio When the setting of 2 in Figure 5 1 is JTAG set the jumper pins JP1 JP6 of this product according to JTAG in Table 5 1 When the setting of 2 in Figure 5 1 is SWD set the jumper pin JP1 JP6 of this product according to the SWD in Table 5 1 1 3 2 Set the debugger e2studio as follows 1 Debug hardware Set according to the type of emulator E2 ARM E2 Lite ARM 2 Type Set according to the comm...

Страница 5: ... according to RE in Table 5 2 Set Power Supply to 3 3V from Tool Details dialog box on the Connect Settings tab Location of 1 in Microcontroller For Ax select RA settings at Jumper Pins In the above example set the jumper pin to RA with A4 For 0E select RE settings at Jumper Pins 1 Figure 5 2 Configuring Renesas Flash Programmer Table 5 2 Jumper Pins JP1 JP6 Settings for Renesas Flash Programmer R...

Страница 6: ...RTE0T00020KCAA0000J User s Manual R20UT5065EJ0100 Rev 1 00 Page 6 of 8 Dec 2021 6 External Dimensions Figure 6 1 External Dimensions 50 mm 40 mm ...

Страница 7: ... equipment Its use outside the laboratory classroom study area or similar such area invalidates conformity with the protection requirements of the Electromagnetic Compatibility Directive and could lead to prosecution The product generates uses and can radiate radio frequency energy and may cause harmful interference to radio communications However there is no guarantee that interference will not o...

Страница 8: ...D ALL WARRANTIES EXPRESS OR IMPLIED WITH RESPECT TO THIS DOCUMENT AND ANY RELATED OR ACCOMPANYING SOFTWARE OR HARDWARE INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE 8 When using Renesas Electronics products refer to the latest product information data sheets user s manuals application notes General Notes for Handling and Using Semiconduc...