RL78/G1G Sensorless Speed control of 120-degree conducting controlled permanent magnetic synchronous motor (Implementation)
R01AN3582EJ0100 Rev.1.00
Page 5 of 46
Jan 13, 2017
1.2.2 Modification when overcurrent detection method is changed
When the overcurrent detection method is changed to "PGA+CMP0, CMP1" from default (INTP0), the 24V Inverter
Board and RL78/G1G CPU Card should be modified per below explanations.
(1) Modification of the 24V Inverter Board
Change 3-Shunt to 1-Shunt.
(1) Connect TH1, TH2 and TH3.
(2) Remove R72 and R97.
TH1
Q2
TH2
Q4
TH3
Q6
R
50
R
72
R
97
Figure 1-3 Change 3-shunt to 1-shunt
Figure 1-4 Modification example on the 24V Inverter Board
(2) Remove
(1) Connect
(1) Connect
(2) Remove