RH850/F1x StarterKit V3 User Manual
R01UH0724ED0120
Page 17
January 2018
4.2.1 Power Supply
4.2.1.1 Power supply configuration
The StarterKit provides two options for powering the board’s integrated circuits. It is possible to
supply the StarterKit by using the E1 Debugger or it is possible to supply the StarterKit by using
an external 12 Volt power supply.
With the default jumper setting (see 0) the StarterKit is configured to be power supplied by the E1
Debugger.
The operation of the LIN and the FlexRay interface is only possible by using an external 12 Volt
power supply.
When the board is supplied externally by 12 Volt, please choose the following jumper settings:
Jumper
Description
Setting
Note
J11
VBAT selector
1-2
closed (12V)
2-3
Open
J10
Voltage regulator output to VDD Connector
(only available on StarterKit Release Version EEAS-0401-002-01)
1-2
closed
Table 4.
Jumper setting for external 12 volt power supply
When the board is supplied by E1 debugger, please choose the following jumper settings:
Jumper
Description
Setting
Note
J11
VBAT selector
1-2
open
2-3
closed (5V)
J10
Voltage regulator output to VDD Connector
(only available on StarterKit Release Version EEAS-0401-002-01)
1-2
open
Table 5.
Jumper setting for power supply by E1 Debugger
The power supply area includes a DC jack type connector for providing external power supply to
the StarterKit and its components. The external supply is reversibly protected against
overvoltage. Nevertheless, please always observe the right polarity and voltage.
Connector
Description
Input Voltage
Range
PowerCon
DC Power Jack ID=2.0mm, center positive
+10V to +15V
Table 6.
Power supply connector specification
The two indicator LEDs (D3 and D4) are showing which power supply voltages are available.