![Renesas QB-78F1026 Скачать руководство пользователя страница 25](http://html1.mh-extra.com/html/renesas/qb-78f1026/qb-78f1026_user-manual_1440292025.webp)
QB-78F1026
CHAPTER 2 SETUP PROCEDURE
R20UT0290JJ0100 Rev. 1.00
Page 19 of 29
Sep 30, 2010
2.5.2 Mounting YQ to TC
(1) After confirming that there are no broken or bent YQ contact pins, fit the YQ in the TC and fasten it using the
supplied YQGUIDE (for the fastening method, see the next step, (2)). If repeatedly inserting and removing, be
sure to inspect the YQ pins before fitting. If pins are bent, correct them using something thin and flat such as
the edge of a knife.
(2) Fasten YQ to the TC on the target system using the supplied YQGUIDE. Fasten the screws equally in the
four corners using the supplied flat-blade screwdriver or a torque driver. The tightening torque of the
YQGUIDE is 0.054 Nm (MAX.). Too great tightening causes bad connections.
However, four screws for fitting to the TC (M2 x 10 mm / 4 units) are included with the YQ.
EA
YQGUIDE supplied with YQ
YQ
TC
Target system
2.5.3 Plugging EA into YQ
Match the pin 1 position of the YQ or SA (corner cuts match in both) to the pin 1 position of the EA and plug in.
- When plugging or unplugging, press on the TC, YQ, and SA with a finger so that there is no force on the TC.
- When plugging or unplugging, be careful of the direction of wiggling.
As a tool when unplugging, insert some kind of thin non-conductive material such as a wooden stick between the
YQ (SA) and EA and wiggle while slowly unplugging. Be careful since the connector will be damaged if this is
done in the wrong direction.