3
4. Jumper and Switch Setting
JP Number
Function
Factory Settings
JP1
Connecting between frame ground of CN5 and signal ground.
It is necessary to cut JP1’s pattern when dividing frame ground and signal ground.
Shorted by
pattern
JP Number
Function
Factory Settings
JP2
Jumper for measurement of 3.3V current.
It is necessary to cut JP2’s pattern when measuring 3.3 V current.
Shorted by
pattern
JP Number
Function
Factory Settings
JP3
Connecting between AGND and DGND
Shorted by
plated wire
JP5
Connecting between frame ground of CN1 and signal ground.
It is necessary to cut JP5’s pattern when dividing frame ground and signal ground.
Shorted by
pattern
JP Number
Position
Function
JP4 (VIF)
“EXIOVcc”
Power is supplied to VIF through CN2-25 and 26.
“3.3V”
VCC and VIF of R8A66597 are supplied from same source.
JP Number
Position
Function
JP6
HOST
CN1-1 (VBUS of USB A receptacle) is connected to VBUS output of U2-5
(VBUS)
OTG
This position is for internal evaluation mode
PERI
CN1-1 (VBUS of USB A receptacle) is connected to VBUS pin of
R8A66597 and CN2-24.
SW Number
Function
Switch to “SEPA”
Separate bus mode is selected.
SW1 (MPBUS)
Switch to “MULT”
Multiplex bus mode is selected.
Содержание M3A-0040