( 26 / 54 )
3.5 Connecting the Target System
Use the suitable converter for your package to connect the emulator MCU and the target system.
For details on the connection to the target system, refer to the Accessory Guide at the URL below.
http://www.renesas.com/en/tools
(3) When Emulator MCU is an RFS or RLFS Chip without Screw-lock
If the emulator MCU is an RFS or RLFS chip without a screw-lock, use the 28DP-WS board as the
probe direction converter board and the PCA4933 (separately available) to connect with the target
system.
Figure 3.7 Connecting the M38000TL2-FPD and RFS chip (without screw-lock)
CAUTION
Notes on Connecting the Target System:
• Always shut OFF power before connecting the target system. The power ON state
could destroy internal circuits.
• The small connector J1 on the tip of the PCA7733 REV.B is guaranteed for only 20
insertion/removal iterations.
• Take care not to attach the converter board in a wrong direction. It may cause a fatal
damage to the emulation pod.
PCA7733 REV.B
28DP-WS
PCA4933
(separately available)
Emulator MCU
without screw-lock
LCC socket
Target system
Connecting procedure
(1) Connect the 28DP-WS and the PCA4933.
(2) Connect the PCA4933 to the RFS/RLFS chip
without screw-lock.
(3) Connect the PCA7733 REV.B and the 28DP-
WS.
Содержание M38000TL2-FPD
Страница 3: ...M38000TL2 FPD User s Manual User s Manual Rev 2 00 2003 11 Emulation Pod for 740 Family MCUs...
Страница 16: ...14 54 MEMO...
Страница 38: ...36 54 Figure 4 3 LED display when self checking...
Страница 50: ...48 54 MEMO...
Страница 54: ...52 54 MEMO...
Страница 56: ...1753 Shimonumabe Nakahara ku Kawasaki shi Kanagawa 211 8668 Japan M38000TL2 FPD REJ10J0072 0200Z User s Manual...