R01UH0092EJ0110 Rev.1.10
Page 420 of 807
Jul 31, 2012
M16C/64C Group
22. Remote Control Signal Receiver
22.2.8
PMCi Data 0 Pattern Set Register (MIN) (PMCiD0PMIN) (i = 0, 1)
PMCi Data 0 Pattern Set Register (MAX) (PMCiD0PMAX) (i = 0, 1)
PMCi Data 1 Pattern Set Register (MIN) (PMCiD1PMIN) (i = 0, 1)
PMCi Data 1 Pattern Set Register (MAX) (PMCiD1PMAX) (i = 0, 1)
When detecting data 0, set the minimum width of the data 0 pattern to the PMCiD0PMIN register and
the maximum width to the PMCiD0PMAX register. Also when detecting data 1, set the minimum width
of the data 1 pattern to the PMCiD1PMIN register and the maximum width to the PMCiD1PMAX
register.
Data 0, data 1, and header or special data pattern must be different values. Also, each value must meet
following:
•
PMCiD0PMIN register value < PMCiD0PMAX register value
•
PMCiD1PMIN register value < PMCiD1PMAX register value
•
Value other than 0000h
Setting value n =
minimum width (maximum width) of data 0/1 pattern
count source
b7
Symbol
PMC0D0PMIN
PMC1D0PMIN
Address
D084h
D098h
Reset Value
00h
00h
b0
Function
RW
PMCi Data 0 Pattern Set Register (MIN) (i = 0, 1)
Set the minimum width of data 0 pattern.
RW
Setting Range
00h to FFh
b7
Symbol
PMC0D0PMAX
PMC1D0PMAX
Address
D085h
D099h
Reset Value
00h
00h
b0
Function
RW
PMCi Data 0 Pattern Set Register (MAX) (i = 0, 1)
Set the maximum width of data 0 pattern.
RW
Setting Range
00h to FFh
b7
Symbol
PMC0D1PMAX
PMC1D1PMAX
Address
D087h
D09Bh
Reset Value
00h
00h
b0
Function
RW
PMCi Data 1 Pattern Set Register (MAX) (i = 0, 1)
Set the maximum width of data 1 pattern.
RW
Setting Range
00h to FFh
b7
Symbol
PMC0D1PMIN
PMC1D1PMIN
Address
D086h
D09Ah
Reset Value
00h
00h
b0
Function
RW
PMCi Data 1 Pattern Set Register (MIN) (i = 0, 1)
Set the minimum width of data 1 pattern.
RW
Setting Range
00h to FFh
Содержание M16C Series
Страница 846: ...M16C 64C Group R01UH0092EJ0110...