HD74LV2GT04A
Rev.2.00, Oct.14.2003, page 4 of 7
Recommended Operating Conditions
Item
Symbol
Min
Max
Unit
Conditions
Supply voltage range
V
CC
3.0
5.5
V
Input voltage range
V
I
0
5.5
V
Output voltage range
V
O
0
V
CC
V
—
6
V
CC
= 3.0 to 3.6 V
I
OL
—
12
V
CC
= 4.5 to 5.5 V
—
–6
V
CC
= 3.0 to 3.6 V
Output current
I
OH
—
–12
mA
V
CC
= 4.5 to 5.5 V
0
100
V
CC
= 3.0 to 3.6 V
Input transition rise or fall rate
∆
t /
∆
v
0
20
ns / V
V
CC
= 4.5 to 5.5 V
Operating free-air temperature T
a
–40
85
°C
Note:
Unused or floating inputs must be held high or low.
Electrical Characteristic
•
Ta = –40 to 85°C
Item
Symbol V
CC
(V) *
Min
Typ
Max
Unit Test condition
3.0 to 3.6
1.5
—
—
V
IH
4.5 to 5.5
2.0
—
—
3.0 to 3.6
—
—
0.6
Input voltage
V
IL
4.5 to 5.5
—
—
0.8
V
3.3
—
0.10
—
Hysteresis voltage
V
H
5.0
—
0.15
—
V
V
T
+
– V
T
–
Min to Max
V
CC
–0.1
—
—
I
OH
= –50
µ
A
3.0
2.48
—
—
I
OH
= –6 mA
V
OH
4.5
3.8
—
—
I
OH
= –12 mA
Min to Max
—
—
0.1
I
OL
= 50
µ
A
3.0
—
—
0.44
I
OL
= 6 mA
Output voltage
V
OL
4.5
—
—
0.55
V
I
OL
= 12 mA
Input current
I
IN
0 to 5.5
—
—
±1
µ
A
V
IN
= 5.5 V or GND
Quiescent
supply current
I
CC
5.5
—
—
10
µ
A
V
IN
= V
CC
or GND,
I
O
= 0
∆
I
CC
5.5
—
—
1.5
mA
One input V
IN
= 3.4 V,
other input V
CC
or GND
Output leakage current I
OFF
0
—
—
5
µ
A
V
I
or V
O
= 0 to 5.5 V
Input capacitance
C
IN
5.0
—
3.0
—
pF
V
IN
= V
CC
or GND
Note:
For conditions shown as Min or Max, use the appropriate values under recommended operating
conditions.