background image

15 

 

Section 5   Notice 

1.  Make sure that pin 1 on the user system IC socket is correctly aligned with pin 1 on the cable head 

before inserting the cable head into the user system IC socket. 

2.  The dimensions of the recommended mount pad for the user system IC socket are different from 

those of the MCU.   

3.  This user system interface cable is specifically designed for the HS2628EPI61H emulator.  Do 

not use this cable with any other emulator station.   

4.  To prevent breaking of wires in the cable body, do not place heavy or sharp metal objects on the 

user system interface cable. 

5.  While the emulator station is connected to the user system with the user system interface cable, 

force must not be applied to the cable head.  Place the emulator station, user system interface 
cable, and user system as shown in the example in figure 10. 

User system

Cable

Emulator station

Place components so that the cable body and cable head are 
parallel to the user system.

Cable head is parallel 

to emulator station

Cable head is parallel 

to user system

 

Figure 10   User System Interface Cable Location Example 

6.  The P1 short connector is used for testing.  Do not remove the jumper pin that is inserted in the 

side of pin 1 and pin 2. 

P1

3

1

 

Figure 11  P1 Short Connector 

Содержание H8S/2628

Страница 1: ...ok over all the business of both companies Therefore although the old company name remains in this document it is a valid Renesas Electronics document We appreciate your understanding Renesas Electron...

Страница 2: ...t for an application categorized as Specific or for which the product is not intended where you have failed to obtain the prior written consent of Renesas Electronics The quality grade of each Renesas...

Страница 3: ...H8S 2628 Group FP 100B User System Interface Cable HS2628ECH61H User s Manual User s Manual Rev 4 0 2004 01 Renesas Microcomputer Development Environment System...

Страница 4: ...described here may contain technical inaccuracies or typographical errors Renesas Technology Corp assumes no responsibility for any damage liability or other loss rising from these inaccuracies or err...

Страница 5: ...system interface cable must only be used for the above purpose Improvement Policy Renesas Technology Corp including its subsidiaries hereafter collectively referred to as Renesas pursues a policy of c...

Страница 6: ...om you Renesas is not liable for any claim made by a third party or made by you for a third party DISCLAIMER RENESAS MAKES NO WARRANTIES EITHER EXPRESS OR IMPLIED ORAL OR WRITTEN EXCEPT AS PROVIDED HE...

Страница 7: ...rt may be reproduced or duplicated in any form in hard copy or machine readable form by any means available without Renesas prior written consent Other Important Things to Keep in Mind 1 Circuitry and...

Страница 8: ...low this symbol to avoid possible injury or death DANGER DANGER indicates an imminently hazardous situation which if not avoided will result in death or serious injury WARNING WARNING indicates a pote...

Страница 9: ...in PERSONAL INJURY The USER PROGRAM will be LOST 1 Do not repair or remodel the emulator product by yourself for electric shock prevention and quality assurance 2 Always switch OFF the E6000 emulator...

Страница 10: ...the Renesas original microcomputer H8S 2628 group The HS2628ECH61H is a user system interface cable that connects an H8S 2628 group E6000 emulator HS2628EPI61H hereinafter referred to as the emulator...

Страница 11: ...IC Socket 5 2 2 2 Soldering IC Socket 5 2 2 3 Inserting Cable Head 6 2 2 4 Fastening Cable Head 6 2 2 5 Fastening Cable Body 8 2 3 Recommended Dimensions for User System Mount Pad 9 2 4 Dimensions for...

Страница 12: ...the user system Figure 1 shows the configuration of the HS2628ECH61H user system interface cable for the FP 100B package User system IC socket Cable head Screws M2 6 x 12 mm with flat washers for fast...

Страница 13: ...ity Remarks 1 Cable body 1 Cable 2 Cable head 1 3 IC socket 1 For the FP 100B package 4 Socket cover 1 For installing an FP 100B packaged MCU 5 Screws M2 6 x 12 mm 4 For fastening cable head with four...

Страница 14: ...make sure that pin 1 on both sides are correctly aligned 2 The user system interface cable dedicated to the emulator must be used To connect the cable body to the emulator station follow the instructi...

Страница 15: ...4 Emulator station E 6 0 0 0 Cable body connector User system interface cable Figure 2 Connecting User System Interface Cable to Emulator Station...

Страница 16: ...sult in PERSONAL INJURY The USER PROGRAM will be LOST To connect the cable head to the user system follow the instructions below 2 2 1 Installing IC Socket After checking the location of pin 1 on the...

Страница 17: ...rewdriver whose head matches the screw head 2 The tightening torque must be 0 0785 N m or less If the applied torque cannot be accurately measured stop tightening when the force required to turn the s...

Страница 18: ...rnating between screws on opposing corners Take special care such as manually securing the IC socket soldered area to prevent the soldered IC socket from being damaged by overtightening the screws or...

Страница 19: ...8 2 2 5 Fastening Cable Body Connect the cable body to the cable head Cable body Cable head Remove jig Push two remove jigs Removing User system Figure 4 Fastening Cable Body...

Страница 20: ...th an IC socket for an FP 100B package IC149 100 054 B51 manufactured by YAMAICHI ELECTRONICS Co Ltd Note that the dimensions in figure 5 are somewhat different from those of the actual chip s mount p...

Страница 21: ...User System Interface Cable Head The dimensions for the user system interface cable head are shown in figure 6 Unit mm Tolerance 0 5 mm 63 5 63 5 17 0 17 0 29 5 29 5 Figure 6 Dimensions for User Syste...

Страница 22: ...fter connecting the user system interface cable head to the user system are shown in figure 7 16 0 21 5 Cable head User system Unit mm Tolerance 0 5 mm IC socket IC149 100 054 B51 manufactured by YAMA...

Страница 23: ...head may break or an IC socket contact error may be caused by a crack in the IC socket solder 4 If the MCU does not operate correctly cracks might have occurred in the solder Check conduction with a...

Страница 24: ...13 MCU Pin 1 IC socket IC149 100 054 B51 manufactured by YAMAICHI ELECTRONICS Co Ltd User system Screws M2 6 x 6 mm with flat washers Socket cover Figure 8 Installing MCU to User System...

Страница 25: ...refer to the H8S 2628 Group E6000 Emulator Supplementary Information HS2628EPI61HE To use the emulator internal clock Select the clock in the emulator station as the system clock by using the CLOCK co...

Страница 26: ...p metal objects on the user system interface cable 5 While the emulator station is connected to the user system with the user system interface cable force must not be applied to the cable head Place t...

Страница 27: ...nual Publication Date Rev 4 00 January 29 2004 Published by Sales Strategic Planning Div Renesas Technology Corp Edited by Technical Documentation Information Department Renesas Kodaira Semiconductor...

Страница 28: ...1753 Shimonumabe Nakahara ku Kawasaki shi Kanagawa 211 8668 Japan H8S 2628 Group FP 100B User System Interface Cable REJ10B0084 0400H HS2628ECH61H User s Manual...

Отзывы: