background image

Cautions 

1.  Renesas neither warrants nor grants licenses of any rights of Renesas’s or any third party’s 

patent, copyright, trademark, or other intellectual property rights for information contained in 
this document.  Renesas bears no responsibility for problems that may arise with third party’s 
rights, including intellectual property rights, in connection with use of the information contained 
in this document. 

2.  Products and product specifications may be subject to change without notice. Confirm that you 

have received the latest product standards or specifications before final design, purchase or use. 

3.  Renesas makes every attempt to ensure that its products are of high quality and reliability. 

However, contact Renesas’s sales office before using the product in an application that demands 
especially high quality and reliability or where its failure or malfunction may directly threaten 
human life or cause risk of bodily injury, such as aerospace, aeronautics, nuclear power, 
combustion control, transportation, traffic, safety equipment or medical equipment for life 
support. 

4.  Design your application so that the product is used within the ranges guaranteed by Renesas 

particularly for maximum rating, operating supply voltage range, heat radiation characteristics, 
installation conditions and other characteristics.  Renesas bears no responsibility for failure or 
damage when used beyond the guaranteed ranges.  Even within the guaranteed ranges, consider 
normally foreseeable failure rates or failure modes in semiconductor devices and employ 
systemic measures such as fail-safes, so that the equipment incorporating Renesas product does 
not cause bodily injury, fire or other consequential damage due to operation of the Renesas 
product. 

5.  This product is not designed to be radiation resistant. 

6.  No one is permitted to reproduce or duplicate, in any form, the whole or part of this document 

without written approval from Renesas. 

7.  Contact Renesas’s sales office for any questions regarding this document or Renesas 

semiconductor products. 

 

 

Содержание H8/3627 Series

Страница 1: ...ok over all the business of both companies Therefore although the old company name remains in this document it is a valid Renesas Electronics document We appreciate your understanding Renesas Electron...

Страница 2: ...t for an application categorized as Specific or for which the product is not intended where you have failed to obtain the prior written consent of Renesas Electronics The quality grade of each Renesas...

Страница 3: ...H8 3627 Series QFP 64E User System Interface Cable HS3627ECN61H for E6000 Emulator User s Manual 8 User s Manual...

Страница 4: ...f bodily injury such as aerospace aeronautics nuclear power combustion control transportation traffic safety equipment or medical equipment for life support 4 Design your application so that the produ...

Страница 5: ...s original microcomputer H8 3627 series The HS3627ECN61H is a user system interface cable that connects an H8 300L series E6000 emulator HS3L08EPI60H hereinafter referred to as the emulator to the IC...

Страница 6: ...et 5 2 2 2 Soldering IC Socket 5 2 2 3 Inserting Cable Head 5 2 2 4 Fastening Cable Head 6 2 2 5 Connecting Cable Body to Cable Head 8 2 3 Recommended Dimensions for User System Mount Pad 9 2 4 Dimens...

Страница 7: ...A Use an IC149 064 075 B51 socket manufactured by YAMAICHI ELECTRONICS Co Ltd for the FP 64E package IC socket on the user system Figure 1 shows the configuration of the HS3627ECN61H user system inter...

Страница 8: ...IC socket Cable head Screws M2 x 12 mm with flat washers Screws M2 x 6 mm with flat washers Socket cover for fastening cable head To emulator station Cable body Figure 1 HS3627ECN61H User System Inter...

Страница 9: ...Remarks 1 Cable body 1 Includes flat cable 2 Cable head 1 3 IC socket 1 For the FP 64E package 4 Socket cover 1 For installing an FP 64E packaged MCU 5 Screws M2 x 12 mm 4 For fastening cable head wit...

Страница 10: ...age the user system and the emulator product or will result in PERSONAL INJURY The USER PROGRAM will be LOST To connect the cable body to the emulator station follow the instructions below 1 Make sure...

Страница 11: ...the location of pin 1 on the IC socket apply epoxy resin adhesive to the bottom of the IC socket for an FP 64E package and fasten it to the user system before soldering 2 2 2 Soldering IC Socket After...

Страница 12: ...ghtening when the force required to turn the screw becomes significantly greater than that needed when first tightening If a screw is tightened too much the screw head may break or an IC socket contac...

Страница 13: ...rs provided Each screw should be tightened a little at a time alternating between screws on opposing corners Take special care such as manually securing the IC socket soldered area to prevent the sold...

Страница 14: ...2 2 5 Connecting Cable Body to Cable Head Connect the cable body to the cable head Cable body Cable head Remove jig Push the remove jig Removing User system Figure 4 Fastening Cable Body 8...

Страница 15: ...e mount pad footprint for the user system with an IC socket for an FP 64E package IC149 064 075 B51 manufactured by YAMAICHI ELECTRONICS Co Ltd Note that the dimensions in figure 5 are somewhat differ...

Страница 16: ...ensions for User System Interface Cable Head The dimensions for the user system interface cable head are shown in figure 6 Unit mm Tolerance 0 5 mm Figure 6 Dimensions for User System Interface Cable...

Страница 17: ...necting User System Interface Cable The resulting dimensions after connecting the user system interface cable head to the user system are shown in figure 7 11 Figure 7 Resulting Dimensions after Conne...

Страница 18: ...w head may break or an IC socket contact error may be caused by a crack in the IC socket solder 4 If the MCU does not operate correctly cracks might have occurred in the solder Check conduction with a...

Страница 19: ...Figure 8 Installing MCU to User System 13...

Страница 20: ...he external clock on the user system as the system clock Select target clock t2 with the CLOCK command emulator command Supply the external clock from the user system to the emulator When a crystal os...

Страница 21: ...input specifications 15 R2 270 R1 1 M HCU04 HCU04 To E6000 emulator OSC1 OSC2 System clock oscillator 0 8 Vcc 55 ns max 55 ns max 0 8 Vcc 0 3 Vcc 0 V Vcc Vcc User System Vcc 3 0 V to 5 0 V 0 3 Vcc Su...

Страница 22: ...tal objects on the user system interface cable 5 While the emulator station is connected to the user system with the user system interface cable force must not be applied to the cable head Place the e...

Отзывы: