background image

Fasten the user system interface cable head to the IC socket for an FP-144H package on the user 
system with the four screws (M2 

x

 12 mm; with four flat washers) provided.  Each screw should be 

tightened a little at a time, alternating between screws on opposing corners.  Take special care, such 
as manually securing the IC socket soldered area, to prevent the soldered IC socket from being 
damaged by overtightening the screws or twisting the components.  

 

Figure 3 

Connecting User System Interface Cable to User System 

 

Содержание FP-144H

Страница 1: ...H8S 2378 Series FP 144H User System Interface Cable HS2378ECH61H for E6000 Emulator User s Manual ADE xxx xxx Rev 2 0 4 1 03 Renesas Technology Corp ...

Страница 2: ...of bodily injury such as aerospace aeronautics nuclear power combustion control transportation traffic safety equipment or medical equipment for life support 4 Design your application so that the product is used within the ranges guaranteed by Renesas particularly for maximum rating operating supply voltage range heat radiation characteristics installation conditions and other characteristics Rene...

Страница 3: ...e Renesas s original microcomputer H8S 2378 Series The HS2378ECH61H is a user system interface cable that connects an H8S 2678R Series E6000 emulator HS2678REPI61H hereinafter referred to as the emulator to the IC socket for a FP 144H package for the H8S 2378 Series MCU on the user system ...

Страница 4: ... IC Socket 5 2 2 2 Soldering IC Socket 5 2 2 3 Inserting Cable Head 6 2 2 4 Fastening Cable Head 6 2 2 5 Fastening Cable Body 8 2 3 Recommended Dimensions for User System Mount Pad 9 2 4 Dimensions for User System Interface Cable Head 10 2 5 Resulting Dimensions after Connecting User System Interface Cable 11 Section 3 Installing the MCU to the User System 12 Section 4 Verifying Operation 14 Secti...

Страница 5: ...ocket manufactured by YAMAICHI ELECTRONICS CO Ltd for the FP 144H package IC socket on the user system Figure 1 shows the configuration of the HS2378ECH61H user system interface cable for the FP 144H package Figure 1 HS2378ECH61H User System Interface Cable 1 ...

Страница 6: ... 1 2 Cable head 1 3 IC socket 1 For the FP 144H package 4 Socket cover 1 For installing an FP 144H packaged MCU 5 Screws M2 x 12 mm 4 For fastening cable head with four flat washers 6 Screws M2 x 8 mm 4 For installing an FP 144H packaged MCU with four flat washers 7 CTS screws M3 x 6 mm 2 For fastening the emulator station 8 Documentation 1 User s manual for HS2378ECH61H this manual ...

Страница 7: ...es are correctly aligned 2 The user system interface cable dedicated to the emulator must be used To connect the cable body to the emulator station follow the instructions below 1 Make sure the user system and emulator station are turned off CAUTION When connecting or removing the user system interface cable apply force only in the direction suitable for connection or removal while making sure not...

Страница 8: ...Figure 2 Connecting User System Interface Cable to Emulator Station 4 ...

Страница 9: ...ult in PERSONAL INJURY The USER PROGRAM will be LOST To connect the cable head to the user system follow the instructions below 2 2 1 Installing IC Socket After checking the location of pin 1 on the IC socket apply epoxy resin adhesive to the bottom of the IC socket for an FP 144H package and fasten it to the user system before soldering 2 2 2 Soldering IC Socket After fastening solder the IC sock...

Страница 10: ...he tightening torque must be 0 294 N m or less If the applied torque cannot be accurately measured stop tightening when the force required to turn the screw becomes significantly greater than that needed when first tightening If a screw is tightened too much the screw head may break or an IC socket contact error may be caused by a crack in the IC socket solder 3 If the emulator does not operate co...

Страница 11: ...ers provided Each screw should be tightened a little at a time alternating between screws on opposing corners Take special care such as manually securing the IC socket soldered area to prevent the soldered IC socket from being damaged by overtightening the screws or twisting the components Figure 3 Connecting User System Interface Cable to User System 7 ...

Страница 12: ...2 2 5 Fastening Cable Body Connect the cable body to the cable head 8 Cable body Cable head User system unfastening jig Push the unfastening jigs Removing Figure 4 Fastening Cable Body ...

Страница 13: ...r the mount pad footprint for the user system with an IC socket for an FP 144H package IC149 144 045 B51 manufactured by YAMAICHI ELECTRONICS CO Ltd Note that the dimensions in figure 5 are somewhat different from those of the actual chip s mount pad Figure 5 Recommended Dimensions for Mount Pad 9 ...

Страница 14: ...2 4 Dimensions for User System Interface Cable Head The dimensions for the user system interface cable head are shown in figure 6 Figure 6 Dimensions for User System Interface Cable Head 10 ...

Страница 15: ...nnecting User System Interface Cable The resulting dimensions after connecting the user system interface cable head to the user system are shown in figure 7 Figure 7 Resulting Dimensions after Connecting User System Interface Cable 11 ...

Страница 16: ...crew head may break or an IC socket contact error may be caused by a crack in the IC socket solder 4 If the MCU does not operate correctly cracks might have occurred in the solder Check conduction with a tester and re solder the IC socket if necessary Check the location of pin 1 before inserting the MCU into the IC socket on the user system as shown in figure 8 After inserting the MCU fasten the s...

Страница 17: ...Figure 8 Installing MCU to User System 13 ...

Страница 18: ...stem For details refer to the Emulator Supplementary Information HS2678REPI61HE To use the emulator internal clock Select the clock in the emulator station as the system clock φ by using the CLOCK command emulator command To use the external clock on the user system Select target clock t or t2 with the CLOCK command emulator command Supply the external clock from the user system to the emulator by...

Страница 19: ...ot use this cable with any other emulator station 4 To prevent breaking of wires in the cable body do not place heavy or sharp metal objects on the user system interface cable 5 While the emulator station is connected to the user system with the user system interface cable force must not be applied to the cable head Place the emulator station user system interface cable and user system as shown in...

Отзывы: