M30850T2-EPB User’s Manual
2. Setup
REJ10J1005-0200 Rev.2.00 April 1, 2007
2.9.3 Connecting to a 100-pin 0.65mm pitch Foot Pattern (Part 2)
Figure 2.10 shows how to connect the emulation probe to a 100-pin 0.65mm pitch foot pattern on the user system with the
M3T-DIRECT100S (not included), and here following is its procedure. For details on the M3T-100LCC-DMS and M3T-
DIRECT100S, refer to each user's manual.
(1) Attach the M3T-DIRECT100S to the user system.
(2) Attach the M3T-100LCC-DMS to the M3T-DIRECT100S.
(3) Attach the M30800T-PTC to the M30850T2-EPB.
(4) Attach the M30800T-PTC to the M3T-100LCC-DMS.
M3T-100LCC-DMS
(not included)
M3T-FLX160-EPB
M30850T2-EPB
CN2 side
(3)
(4)
M30800T-PTC
(2)
(1)
100-pin 0.65mm pitch
(PRQP0100JB-A) foot pattern
No.1 pin
User system
M3T-DIRECT100S
(not included)
Figure 2.10 Connecting to a 100-pin 0.65mm pitch foot pattern (2/3)
CAUTION
Notes on Connecting the User System:
z
Take care not to attach the converter board in a wrong direction. It may cause a fatal damage to the emulator.
z
The small connectors of the M3T-100LCC-DMS and M3T-DIRECT100S are guaranteed for only 20
insertion/removal iterations.
z
The small connectors of the M30850T2-EPB and M30800T-PTC are guaranteed for only 50 insertion/removal
iterations.
Page 32 of 98
Содержание Emulation Probe M30850T2-EPB
Страница 98: ...M30850T2 EPB User s Manual...