3.3 Selecting Clock Supply
There are two ways to supply a clock to the MCU, using the oscillator circuit of the emulation pod
or using the oscillator circuit on the target system. Table 3.2 lists the factory-settings of each clock
supply.
Table 3.2 Clock supply to the MCU
Clock
Description
Display of emulator debugger
Default setting
X
IN
-X
OUT
X
CIN
-X
COUT
Internal oscillator circuit of emulation pod
(OSC-3: 10MHz)
Target System
Internal oscillator circuit of emulation pod
(OSC-2: 32.768kHz)
Target System
Internal
External
External
Internal
O
-
-
O
IMPORTANT
Notes on Changing the Clock Supply:
• The clock supply can be set by the Init dialog when starting up the emulator debugger
or inputting CLK command on the script window.
• For X
CIN
-X
COUT
pins, it is necessary to set switches in the emulation pod. For details,
refer to "3.2 Switch Settings" (page 25).
Содержание Emulation Pod M306V2T-RPD-E
Страница 3: ...M306V2T RPD E User s Manual User s Manual Rev 1 00 2003 09 Emulation Pod for M306V2 M306V5 MCUs ...
Страница 8: ... 6 72 MEMO ...
Страница 46: ... 44 72 Figure 4 4 Self check procedure ...
Страница 59: ... 57 72 Figure 5 7 Connection diagram 2 Control signal ...
Страница 62: ... 60 72 MEMO ...
Страница 68: ... 66 72 MEMO ...
Страница 72: ... 70 72 MEMO ...
Страница 74: ...1753 Shimonumabe Nakahara ku Kawasaki shi Kanagawa 211 8668 Japan M306V2T RPD E REJ10J0266 0100Z User s Manual ...