M3062PT3-RPD-E User’s Manual
3. Usage (How to Use the Emulator Debugger)
REJ10J0040-0600 Rev.6.00 July 01, 2006
Page 51 of 104
3.2 Setting the Work Area
With this product, the emulator uses 54 bytes as a work area in emulation memory. Therefore, according to the memory
mapping of the MCU you use, specify the work area addresses.
In single-chip mode, set the work area address at 10000h.
In memory expansion or microprocessor mode, the areas listed below cannot be used as a work area, specify a work area other
than the areas listed below. And the top address of the work area should be an even-numbered address.
(1)
SFR area (00000h--003FFh)
(2)
External area of multiplex bus setting
(3)
Reserved area of 27000h--27FFFh
(4)
Stack area used by the emulator for reset command execution (0FFF9h--0FFFFh)
(5)
F6000h to F63FFh and F8000h to F83FFh
The area used as a work area (54 bytes) is specified in the F/W and Work Area tab of the INIT dialog box of the emulator
debugger. And set the work area as MAP=INT.
Содержание Emulation Pod M3062PT3-RPD-E
Страница 104: ...M3062PT3 RPD E User s Manual...