( 29 / 74 )
3.3 Selecting Clock Supply
There are two ways to supply a clock to the MCU, using the oscillator circuit of the emulation pod
or using the oscillator circuit on the target system. Table 3.4 shows the factory-settings of each clock
supply.
Table 3.4 Clock supply to the MCU
IMPORTANT
Notes on Changing the Clock Supply:
• The clock supply can be set by the Init dialog when starting up the emulator debugger
or inputting CLK command on the script window.
• For X
CIN
-X
COUT
pins, it is necessary to set switches in the emulation pod when using
the clock on the target system. For details, refer to "3.2 Switch Settings" (page 25).
Clock
Description
Display of emulator debugger Factory-setting
X
IN
-X
OUT
X
CIN
-X
COUT
Internal oscillator circuit of emulation pod
(OSC-3: 20 MHz)
Target system
Internal oscillator circuit of emulation pod
(32.768 KHz)
Target system
Internal
External
External
Internal
Yes
-
Yes
-
Содержание Emulation Pod for M16C/80 Group MCUs M30803T-RPD-E
Страница 3: ...M30803T RPD E User s Manual User s Manual Rev 1 00 2003 07 Emulation Pod for M16C 80 Group MCUs...
Страница 8: ...6 74 MEMO...
Страница 18: ...16 74 MEMO...
Страница 46: ...44 74 MEMO...
Страница 56: ...54 74 Figure 4 5 Self check procedure...
Страница 60: ...58 74 Figure 5 2 Connection diagram 2 2...
Страница 70: ...68 74 MEMO...
Страница 74: ...72 74 MEMO...
Страница 76: ...1753 Shimonumabe Nakahara ku Kawasaki shi Kanagawa 211 8668 Japan M30803T RPD E REJ10J0197 0100Z User s Manual...