CPX4 AC-PLC Evaluation Kit M02D2 RTK0EE0009D02001BJ
3
.
Interface Specifications
R30UZ0165EJ0100 Rev.1.00
Page 17 of 53
July 01, 2021
Table 1-2 List of specifications
Product name
CPX4 AC-PLC Evaluation Kit M02D2 RTK0EE0009D02001BJ
Product Model Number
RTK0EE0009D02001BJ
PLC modem device
CPX4 (R9A06G061)
Control MCU
RX651 (R5F5651EHDFP)
AFE Devices
ISL15102 (Intersil) : Power Amp (hereinafter, PA) + RX Step ATT : discrete
PLC section specifications
Applicable Frequency
35kHz – 500kHz
Applicable power line
voltage
AC100-230V
Applicable standards
CENELEC-A (35.9375kHz - 90.625kHz), CENELEC-B (98.4375kHz - 121.875kHz),
G3-FCC (154.6875kHz - 487.5kHz)
Legal compliance*1
CE and UKCA Certifications (EN500650-1, 2-3, 4-2, 7)
FCC Certifications (FCC part15 subpart B 15.107, 109)
Power supply
External power supply via AC adapter (rated 15V/1.2A)
Interface
AC-PLC Board
PLC Signal Port (AC inlet)
PLC connector (CN3): AC power cable connection for
PLC signal
External power supply port
Power connector (CN4): AC jack
AC-adapter for supplying power: Connect DC15V or
DC12V (Note:AC adapter is not included)
PMOD
Connector for Digilent Pmod™ interface (PMOD1):
Type 2A(SPI) / Type 4A(UART) supported
USB
USB connector (CN5): for serial communication with
CPX4, Mini-B USB cabling for PC communication
RX651 MCU
Board
MCU(RX651)
On-chip debugging
OCD connector (CN305): MCU(RX651) E1 emulator
connection for debugging
GPIO(MCU)
GPIO connectors (CN301): For MCU signal
monitoring
USB
USB connector (CN302): For USB function and USB
boot mode
Filter board
RX band pass filter
Applicable Frequency
A2-type(35k-90kHz), F2-type(150k-500kHz), G2-
type(35k-500kHz)
Product description
・
AC-PLC Board································1 unit
・
RX651 MCU Board················ ···········1 unit
・
Filter board (A2/F2/G2-type)·········· ······3 unit
・
PMOD conversion board··············· ······1 unit
・
USB cable··················· ···················1 pcs
・
Precautions for Use (English) ················ 1 pcs
・
Precautions for Use (Japanese) ·············1 pcs
・
SJ/T 11364 table of hazardous substance (China RoHS)·····1 pcs
External Dimensions
AC-PLC board : 130×80×45 mm
Note *1 : This product has not obtained ARIB certification in Japan, it is not possible to perform communication tests
using commercial power supplies in Japan. When conducting a communication test using a commercial power source, it
is necessary to submit an application for high-frequency use equipment and obtain permission from the Ministry of
Internal Affairs and Communications.