background image

( 3 / 4 )

5. Connection Procedure 

(See Figure 3)

The procedure for connecting the M3T-F160-100NSE is
shown below.

(1) Mount the NQPACK100SE on the target system.

(2) Attach the YQPACK100SE on the NQPACK100SE.

(3) Secure the four corners of the YQPACK100SE with the

YQ-GUIDE's.

• Do NOT use the screws included with the

YQPACK100SE.

• Do NOT use the screwdriver included with the

NQPACK100SE that is used only for the
HQPACK100SE. It is not for the YQ-GUIDE's.

(4) Attach the probe of the emulation pod to the M3T-F160-

100NSE.

(5) Attach the M3T-F160-100NSE on the YQPACK100SE.

Figure 3 Connection procedure

6. External Dimensions and a Sample Foot Pattern

Figure 4 External dimensions and a sample foot pattern

Unit: mm

M3T-F160-100NSE

YQ-GUIDE's (x4)

YQPACK100SE

NQPACK100SE

100-pin 0.4-mm-pitch

(100PFB-A) foot pattern

FLX160-PRB

or

M3xxxxTx-EPB

Use a slotted screwdriver.

: Position of No. 1 pin

Be sure to align the pins.