Section 9. Trouble-Shooting
The following are a few suggestions on how to perform a basic troubleshooting, if the emulator does not
respond to the user’s commands.
Symptoms
Checks
Expected Observation & Action
Power Supply
POWER LED lights up in Red.
PC Bios setup
USB must be enabled
Window Device
Manager
USB do not have any contention. Compact Emulator
must be detected instead of a USB device.
Standalone Self
Test
POWER LED lights up in Orange denoting entering self
test mode
Adjacent RUN LED do not light up after the test,
Blinking POWER LED
USB cable and
connector contacts
Clean the contact.
Change the USB cable.
Cannot link to
PC
Target System
Is user supply provided to the target?
HEW Setup
Has HEW been setup in the PC?
Clock setting
Is clock set to “target”?
Is there any clock signal input to the emulator?
Mode setting
Is mode set to “target”?
Reset setting
Is reset masked in the HEW configuration platform
window?
STBY setting
Is STBY masked in the HEW configuration platform
window?
Cannot run
code on target
NMI
Is NMI masked in the HEW configuration platform
window?
Power Supply
Is Target supplying power to the emulator?
Cable detection
Has HEW detected the Cable?
Is CABLE_IN_N tied to ground in the target system?
Target connection
Is the target connection tight and secure?
Signal level
Is the emulator pull-up resistors driving the target
system?
69
www.DataSheet4U.com
Содержание CE2000-H8S Series
Страница 2: ...Blank Page www DataSheet4U com...
Страница 22: ...Blank Page 8 www DataSheet4U com...
Страница 41: ...Blank Page 27 www DataSheet4U com...
Страница 57: ...Figure 6 1 Basic Bus Cycle Timing in Expanded mode 43 www DataSheet4U com...
Страница 59: ...Blank Page 45 www DataSheet4U com...
Страница 84: ...70 Blank Page www DataSheet4U com...
Страница 88: ...Part Number 8830E 080 170S Unit mm inch B 2 www DataSheet4U com...
Страница 95: ...Renesas Technology Asia Sales Offices URL http www renesas com G 1 www DataSheet4U com...
Страница 96: ...CE2000 www DataSheet4U com...