Section 5. Differences between H8S Microcomputer and
Emulator
5.1 Power up and reset
When the emulator initialises the system or resets the Microcomputer as a result of a command such as
switching the clock, or when the reset command is used, note that the general-purpose registers and part
of the control registers are initialized.
Table 5-1
Differences between H8S and Emulator
Status
Register
Emulator
H8S
PC
Power on reset vector value
Power on reset vector value
ER0 to ER6 H’00000000
Undefined
ER7 (SP)
H’FFEFBC
Undefined
CCR
The I mask is set to 1 and the
other bits are undefined
(B’1-------)
The I mask is set to 1 and the
other bits are undefined
(B’1------)
EXR
Trace bit is set to 0 and the
interrupt bits are set to 1
(B’0----111)
Trace bit is set to 0 and the
interrupt bits are set to 1
(B’0----111)
Emulator
Initialisation
(power on)
PC
Power on reset vector value
Power on reset vector value
ER0 to ER6 Undefined
Undefined
ER7 (SP)
Undefined
Undefined
CCR
The I mask is set to 1 and the
other bits are undefined
(B’1-------)
The I mask is set to 1 and the
other bits are undefined
(B’1------)
EXR
Trace bit is set to 0 and the
interrupt bits are set to 1
(B’0----111)
Trace bit is set to 0 and the
interrupt bits are set to 1
(B’0----111)
Emulator
Initialisation
(reset
command)
40
www.DataSheet4U.com
Содержание CE2000-H8S Series
Страница 2: ...Blank Page www DataSheet4U com...
Страница 22: ...Blank Page 8 www DataSheet4U com...
Страница 41: ...Blank Page 27 www DataSheet4U com...
Страница 57: ...Figure 6 1 Basic Bus Cycle Timing in Expanded mode 43 www DataSheet4U com...
Страница 59: ...Blank Page 45 www DataSheet4U com...
Страница 84: ...70 Blank Page www DataSheet4U com...
Страница 88: ...Part Number 8830E 080 170S Unit mm inch B 2 www DataSheet4U com...
Страница 95: ...Renesas Technology Asia Sales Offices URL http www renesas com G 1 www DataSheet4U com...
Страница 96: ...CE2000 www DataSheet4U com...