3.1 Package information
3. Installation and startup
Figure 3-1 package information
3.2 Installation environment
1) In order to achieve optimal performance, the ambient temperature should be kept lower than 45 °C.
2) For the convenience of checking the LCD display and possible maintenance activities, please install the inverter at eye level.
3) Inverters should NOT be installed near inflammable or explosive items. Any strong electro-magnetic equipment should be
kept away from installation site.
4) Product label and warning symbol shall be clear to read after installation.
5) Please do not install inverter under direct sunlight, rain and snow.
Warning
!
Before installation and maintenance, AC and DC side doesn’t carry electricity, but if DC side is
just disconnected, capacitance still contains electricity, so please wait for at least 5 minutes
to ensure the capacitors completely release the energy and inverter is not electrified.
Note
!
Inverters must be installed by qualified person.
①.There are 2 PV connectors for R3-4/5/6/8/10/12K-DT and 3 PV connectors for R3-15K-DT
②.There are 2 PV connectors for R3-4/5/6/8/10/12K-DT and 3 PV connectors for R3-15K-DT
Quality Certificate
Model:
QC:
This is to verify that the product
is qualified to delivery
Product Test Report
Product
QC:
1
2
3
4
5
6
7
8
9
10
Conclusion:
Pass
NG
Pass
Pass
Pass
Pass
Pass
Pass
Pass
Pass
Pass
Pass
Text Items
Production Date
SN
xxxx
xxxx
xxxxxxxxx
xxxx
xxxx
xxxx
xxxx
xxxxxxxxx
xxxx
xxxxxxxxx
xxxx
xxxxxxxxx
xxxx
xxxxxxxxx
xxxx
xxxxxxxxx
xxxx
xxxxxxxxx
xxxx
xxxxxxxxx
xxxx
xxxxxxxxx
xxxx
xxxxxxxxx
INVERTER*1
MOUTING PANEL*1
PV CO)
1
PV CONNETOR(-)
2
GPRS/WIFI(OPT.)
EXPANSION TUBE*4
FACTORY REPOER*1
SCREW*1
QC PASS*1
QIG*1
In consideration of heat dissipation and convenient dismantlement, the minimum clearances around the inverter should be
no less than the following value.
3.3 Installation position
1) The installation method and mounting location must be suitable for the inverter's weight and dimensions.
2) Mount on a solid surface.
3) Select a well-ventilated place sheltered from direct sun radiation.
Figure 3-3 Distance required of Invertors
Figure 3-2 installation position
Figure 3-2 installation environment
Max 15°