The following is the description of working modes:
Work mode
Parameter
Comment
Force Time Use
Charger start time 1
The start time of the first
charger period.
Charger end time 1
The end time of the first
charger period.
Charger start time 2
The start time of the second
charger period.
Charger end time 2
The end time of the second
charger period.
Discharger start time 1
The start time of the first
discharger period.
Discharger end time 1
The end time of the first
discharger period.
Discharger start time 2
The start time of the second
discharger period.
Discharger end time 2
The end time of the second
discharger period.
Self Use
N/A
The default work mode of the
inverter.
FFR use
N/A
Firm Frequency Response.
Remote Charge
N/A
Remotely Charge / Discharge
battery through RS485.
External Use
N/A
Remote control mode, local
EMS unit to control two value:
Solar power and battery
power.
H) Export control
With this function the inverter can control the energy exported to the grid. There are user value
and factory value. The factory value is default which cannot be changed by user. The user value
setting by installer must be less than the factory value. Press up and down button to select and
press
“OK” to confirm.