6.7 Connections of the ESC-Hybrid system
The Overview of the connection terminals of inverter please refer to Figure 3-1, and the detailed
wiring connections please refer to Figure 2-1 the ESC system wiring diagram in chapter 3.1.
The main steps to connect the ESC-Hybrid system
PV string connection
AC output connection
Battery connection
Battery power connection
Battery communication connection
Battery thermal sensor connection
EPS connection
Earth connection
Communication connection
6.7.1 PV string connection
WARNING!
PV module voltage is very high which belongs to dangerous voltage
range, please comply with electric safety rules when connecting.
When the photovoltaic array is exposed to light, it supplies a D.C voltage
to the PCE.
When there is something wrong with the modules arrays. Modules can be
connected with inverter only after eliminating these problems.
ESC-hybrid series inverters can be connected in series into 2-strings PV modules, please select
PV modules with excellent function and reliable quality.
Open-circuit voltage of module arrays connected in series should be <Max. DC input voltage;
operating voltage should be conformed to MPPT voltage range.
Please use PV cable to connect modules to inverter. From junction box to inverter, voltage drop
is about 1-2%. So we suggest the inverter install near PV module, in order to save cable and
reduce DC loss. (No longer than 30m)
NOTE!
The following requirements of PV modules need to be applied for each
input area;
• Same type • Same quantity • Identical alignment • Identical tilt
Please do not make PV positive or negative ground!