13
Important Information
After all learning completed, User can go back to the ZXT-600
control page on the gateway for normal operation.
• On the Gateway UI, User can only use the Temperature range
from the mapping table, OFF, ON(RESUME), COOL, HEAT, DRY
MODE, AUTO MODE and FAN MODE.
• If User only learnt ON(RESUME), OFF, or part of the settings
according to the above table, ZXT-600 will send the learnt data
to the Air Conditioner only. For example, User only learnt ON(RE-
SUME), OFF, 22°C COOL, 24°C HEAT, ZXT-600 will not send the IR
Data to Air Conditioner if User set 27°C Cool on the gateway.
• User can still use gateway to set up Scene and Schedule with
ZXT-600. For example, to have AC turn on at 23°C every day at
7am, 25°C at 11pm. Just make sure the set code is learnt.
• The learning mapping table is for split Air Conditioner, which Re-
mote Control is with LCD Display. For Window type Air Condition-
er (which Remote Control is without LCD Display), the mapping
table with temperatures do not apply, due to different type of IR
Control Protocol. However, User may still use OFF, ON(RESUME),
DRY, AUTO or FAN Key for Learning.
• (Because the POWER key on the Original Remote (without LCD
Display) is toggle, user can choose either ON key or OFF key to
learn Power key. After Learning is done, press once to turn on the
Air Conditioner if the Air Conditioner is OFF, press once to turn
OFF if the Air Conditioner is ON)
Содержание AC MASTER
Страница 1: ...ZXT 600 AC MASTER INSTALLATION GUIDE ...
Страница 2: ......