2.2 System layout WKF/WKF-compact 100/130
A
B
C
1
2
1
3
4
5
6
7
C
2
D
1
D
2
2
3
4
5
8
9
8
9
10
11
12
Fig. 2: System layout
A:
Outdoor area
B:
Indoor area
C1: Indoor unit WKF-compact 100/130
C2: Indoor unit WKF 100/130
D1: Outdoor unit WKF-compact 100/130
D2: Outdoor unit WKF 100/130
1:
Common return flow (DN 25)
2:
Condensate drain, outdoor unit (must contain
anti-freeze!)
3:
Refrigerant lines
3
/
8
" and
5
/
8
“
4:
Outdoor unit power supply = 230V/1~/50Hz
20A (e.g. 3x2.5 mm
2
)
5:
Indoor unit power supply = 230V/1~/50Hz
16A (e.g. 3x1.5 mm
2
)
6:
Power supply for electrical auxiliary heater 6 kW
(e.g. 5x2.5 mm
2
)
7:
Power supply for electrical auxiliary heater 6 kW
(optional) (e.g. 5x2.5 mm
2
)
8:
Control line shielded (e.g. 2x1 mm
2
)
9:
Fan
10: Inlet for heating (DN 32)
11: Hot-water supply and return pipes (DN 32)
12: Inlet for hot-water tank (DN 32)