Ventilation

 

In this position only the supply air fan runs. The thermo-
static regulation and the heating operation is not possible 

Attention, important hints to the 

after-cooling phase.

 

The air supply fan continues running to cool down 
the unit and then stops later.  

Fan can start several times before final switching off.

 

Never interrupt (except in emergency situations) the 
connection to the mains before the end of the whole 
after-cooling phase. 

Unit Shut Down

 

Heating  

The unit runs fully automatically and is dependent on set 
temperatures. 

If the temperature at the blower aperture rises above 
80° C the heating operation is stopped and will restart 
after the cooling-down period automatically. 

1.   Put operating switch into        

position “1”          

Ventilation

 

G

 

Our guarantee does not cover damages caused to 
the unit by overheating. 

1.   Put operating switch into        

position “0”.         

OFF

”. 

0

3

1.   Pre-select desired room tem-

perature on the room thermo-
stat. 

2.   Put operating switch into desired 

position (2 or 3) depending on the 
desired heating capacity. 

3

2

1

0

40 

OFF 

G

 

For optimum unit operation, the device should not 
be operated at an ambient temperature above 25 °C. 

Maintenance and Service

 

 
Regular maintenance and the observation of some ba-
sic principles is important to ensure a long service life 
and a trouble-free operation of the unit. 

Please pay attention to the following points:

 

The unit is to be maintained and cleaned in regular 
intervals.

 

The unit is to be kept free from dust and other de-
posits and is to be cleaned only with a dry or humid 
cloth.         

Do not use water jet.

 

Do not use any aggressive cleaning agents or those 
which are harmful or environmentally unfriendly.

 

Do not use cleaning agents which contain solvents. 

Only use suitable cleaning agents to remove ex-
treme dirt. 

Check safety devices regularly.

 

Check protective suction and blower grids regularly 
and clean, when necessary.

 

Do not damage the sensor and capillary tube of the 
thermostat when the rear panel is installed or re-
moved.

 

According to the terms of use the units are to be 
checked as to their perfect operation by an expert 
when necessary, but at least once a year. 

Please carry out an electrical safety test after having 
finished service on the unit. 

G

 

Prior to starting any work make sure to pull the 
mains plug out of the mains socket!

 

Correct usage 

The units are to be used only for heating and ventilation 
purpose in industrial or commercial application because 
of their construction and equipment. If specification of 
the manufacturer or legal regulations, are not followed 
or if unauthorised changes are made on the unit, the 
manufacturer is not liable for resulting damages. 

G

 

An operation/use other than that indicated in these 
instructions is prohibited!  
In the case of non-observation we will not be held 
responsible and our guarantee will become void.

 

Service and Guarantee

 

 
Any claims under guarantee regarding materials can be 
accepted only when the orderer or his customer has 
filled in completely the “guarantee certificate” which is 
enclosed with every REMKO-heater and has returned it 
to REMKO GmbH & Co. KG in due time after the unit’s 
sale and commissioning. The units are factory tested on 
faultless function. If any failures  occurs though which 
cannot be eliminated by the operating person, please 
contact your dealer or contact person. 