4
Safety Instructions
REMKO electric heaters will provide you with high utility
and long life thanks to our extensive material, function
and quality controls. Dangers may arise nevertheless if
the unit is used by persons not familiar with its operation
or if the unit is not used for its intended purpose.
Please pay attention to the following points:
◊
The persons charged with the operation of the units
have to check these before starting work as to visible
defects of the operation and safety devices, as well as
to make sure that no protective devices are missing.
In the case of faults the supervisor is to be informed.
◊
In the case of faults which endanger the safe opera-
tion of the units, the units are to be stopped!
◊
During the operation of the units the applicable local
regulations are to be observed and the relevant
safety measures to be taken.
◊
Make sure that the prescribed safety distances from
combustible objects are observed!
◊
A free air suction and air discharge must be ensured
◊
The blow off opening of the unit may not be narrowed
or equipped with hoses or conduits.
◊
Never place foreign objects into the unit.
◊
Do not cover the units during operation.
◊
The units may not be operated near bath tubs, show-
ers, swimming pools, etc.
◊
The units may not be operated directly beneath a wall
socket.
◊
The units may not be exposed to direct water jets.
◊
Make sure that no water penetrates inside the units.
◊
The units may not be operated in rooms which are
endangered by explosions.
◊
Protect all electric cables outside the units from
damage (e.g. caused by animals).
Starting
A well trained person is to be charged with the operation
and control of the units.
1. Check the main voltage is in accordance with the
unit voltage.
400V / 3~, PE / 50 Hz.
Description of Device
The units are operating with electric energy and are suit-
able for a fully automatic, all-purpose and simple appli-
cation.
The units are equipped with capsuled electrical heating
elements, room thermostat, noiseless maintenance-free
axial fans, safety and after-cooling thermostat, 3-stage
operating switch.
The units are in accordance with the basic safety and
health requirements of the relevant EC – regulation.
The units are handled simply and are safe in operation.
3. Connect the CEE-unit plug with an extension cable
according to the regulations to an adequate CEE-
mains socket.
2. Put operating switch into
position "0".
0
3
G
The electric connection of the units is to be carried
out via a special supply point with fault current
safety switch.
Application
◊
Drying of new buildings, spot heating of working places
outside or in fire-proof halls and production places.
◊
Permanent or temporary heating of rooms.
◊
Defrosting of machines vehicles and fire-proof storing
goods with keeping the prescribed distance of safety.
Working of device
The units are equipped with a 4-stage operating switch.
In the first stage only the supply air fan is operated and
the units can be used for air circulation.
In the 2nd – 3th. stage the heating elements are acti-
vated and hot air is discharged.
The units are operated with a room thermostat to en-
sure a constant room temperature. When the pre-
selected temperature has been reached, the thermostat
stops the heating operation to restart it when the tem-
perature has fallen below the set value.
When the units have been switched off by the operating
switch or the room thermostat, the supply air fan contin-
ues running for a certain time to cool down the heat ex-
changer, and then it stops automatically.
G
Never interrupt (except in emergency situations)
the connection to the mains before the end of the
whole after-cooling phase.
G
Connecting cable extensions may be laid exclu-
sively by authorised electricians based on the unit
capacity, cable length and taking the local terms of
use into account.
Содержание TX 9000
Страница 2: ......