2
Technical data
2.1 Unit data
Series
RVT 265 DC
RVT 355 DC
Operating mode
Inverter wall-mounted room air conditioner com-
bination for cooling and heating
Nominal cooling output
1)
kW
2.63 (0.99-4.15)
3.52 (1.03-4.81)
Energy efficiency ratio SEER
1)
9.2
9.0
Rated power consumption, electrical cooling
1)
kW
0.483
0.75
Rated elec. curr. consump., cooling
1)
A
2.1
3.3
Power consumption, annual, Q
CE
3)
kWh
102
137
Energy efficiency ratio, cooling
1)
A+++
Nominal heat capacity
2)
kW
4.10 (0.75-6.99)
4.24 (0.75-7.19)
Energy efficiency ratio SCOP
4)
5.3
Rated power consumption, electrical heating
2)
kW
0.834
0.943
Rated elec. curr. consump., heating
2)
A
3.6
4.1
Power consumption, annual, Q
HE
3)
kWh
643
647
Energy efficiency ratio, heating
2)
A+++
Max. power consumption
kW
2.42
3.11
Max. current consumption
A
10
13
EDP no.
1623750
1623760
Data specific to indoor unit (IT)
RVT 265 DC
RVT 355 DC
Application area (room volume), approx.
m
3
80
100
Adjustment range, room temperature
°C
+16 to +32
Operating range
°C
+16 to +30
Air flow volume per stage
m
3
/h
285/380/430/500/565
310/380/450/530/590
Sound pressure level per stage
5)
dB (A)
23/26/29/33/28
28/31/34/37/40
Sound pressure level, Silent/Turbo mode
5)
dB (A)
22
21
Sound power level max.
dB(A)
58
59
Enclosure class
IP
X0
Condensate drainage connection
mm
18
Dimensions: H/W/D
mm
298/895/248
Weight
kg
13
EDP no.
1623752
1623762
9