Heating capacity RVT 684 DC
0,00
0,50
1,00
1,50
2,00
2,50
3,00
3,50
4,00
4,50
5,00
5,50
6,00
6,50
7,00
7,50
8,00
8,50
9,00
9,50
-20
-15
-7
2
7
12
2
1
3
A
[°C]
Fig. 10: Performance curves, heating RVT 684 DC (data for room temperature 20 °C)
A: Outside temperature
1: COP
2: Heating capacity in kW
3: Power consumption in kW
Outside temperature in °C
-20
-15
-7
2
7
12
Heating capacity in kW
3.62
4.16
4.39
6.08
7.62
8.67
Power consumption in kW
1.85
1.87
1.89
2.06
2.21
2.21
COP
1.96
2.23
2.32
2.95
3.45
3.87
Cooling capacity RVT 684 DC
0,00
0,50
1,00
1,50
2,00
2,50
3,00
3,50
4,00
4,50
5,00
5,50
6,00
6,50
7,00
7,50
8,00
21
25
30
35
40
45
50
2
1
3
A
[°C]
Fig. 11: Performance curves, cooling RVT 684 DC (data for room temperature FK27°/TK19 °C)
A: Outside temperature
1: EER
2: Cooling capacity in kW
3: Power consumption in kW
Outside temperature in °C
21
25
30
35
40
45
50
Cooling capacity in kW
7.08
7.55
7.61
7.33
6.29
5.96
5.81
Power consumption in kW
1.76
1.90
2.07
2.26
2.29
2.33
2.42
EER
4.02
3.97
3.68
3.24
2.74
2.55
2.40