REMKO RR

Carefully read the operating manual 
before placing the unit or components 
into service for the first time. It provides 
useful tips,   notes and   hazard 
warnings to prevent injury and material 
damage. Failure to follow the directions 
in this manual can endanger persons, 
the environment and the equipment 
itself and will void any claims for liability.

■ 

Keep this manual in the vicinity of the 

units or components.

■ 

Only qualified personnel may set up 

and install the units or components.

■ 

The unit or its components must be 

set-up, connected and operated in 

accordance with the use and operating 

conditions stipulated in this manual 

and comply with all applicable local 

regulations. 

■ 

Modification of the units and 

components supplied by REMKO 

is not permitted and can cause 

malfunctions.

■ 

Units and components may not be 

operated in areas where there is an 

increased risk of damage. Observe the 

minimum clearances.

■ 

The electrical power supply is to be 

adapted to the requirements of the 

units or components.

■ 

The operational safety of units or 

components is only assured if they are 

fully assembled and used as intended. 

Safety devices may not be modified or 

bypassed.

Safety notes

■ 

Do not operate units or components 

if there are obvious defects or signs of 

damage.

■ 

The units or components must be 

kept at an adequate distance from 

flammable, explosive, combustible, 

abrasive and dirty areas or atmospheres.

■ 

Installation, repair and maintenance 

work may only be carried out 

by authorised specialists. Visual 

inspections and cleaning can be 

performed by the operator as long 

as the unit is disconnected from the 

power.

■ 

To preclude any risks to persons 

originating from the units or 

components, appropriate precautions 

must be taken when installing, 

repairing, maintaining, cleaning or 

working on the units.

Intended use

Depending on the design and 
equipment, the components are 
intended exclusively for installation in 
dry rooms and for controlling cold water 
indoor units.
Any different or additional use is 
non-intended use. The manufacturer / 
supplier assumes no liability for damages 
arising from non-intended use. The user 
bears the sole risk in such cases.
Intended use also includes working 
in accordance with the operating and 
installation instructions.

Содержание RR 22.0

Страница 1: ...REMKO RR 22 0 Room temperature controller KWK 130 to 870 KWK 130 to 870 ZW KWD 25 to 100 EC WLT 25 to 85 S DKT 21 4 to 71 4 Operation Technology Edition GB N01...

Страница 2: ......

Страница 3: ...ssioning 11 Technical data 11 Electrical wiring diagram two wire system 12 19 Electrical wiring diagram four wire system 20 21 Carefully read this operating manual prior to commissioning using the uni...

Страница 4: ...safety of units or components is only assured if they are fully assembled and used as intended Safety devices may not be modified or bypassed Safety notes Do not operate units or components if there a...

Страница 5: ...tions are listed in the General terms and conditions Please contact your direct contractual partner in the first instance Environmental protection and recycling Disposal of packaging All products are...

Страница 6: ...sary also use the operating instructions of the unit being operated Mode selector switch The key is used to switch off O of the controller and to select the operating mode Heating or Cooling Fan selec...

Страница 7: ...carried out as fixed connections in accordance with the applicable regulations 5 Check the jumper settings and adjust them if necessary 6 Check the terminals are tight 7 Re attach the cover Installat...

Страница 8: ...can be used to control a system with a cooling valve and a further heating valve in a four wire system a system with a valve controlled half yearly generated warm medium in winter e g through a boile...

Страница 9: ...eration in heating mode when a minimum temperature is reached see chapter Minimum temperature medium The maximum cable length of 25 m must not be exceeded External room temperature probe SA terminal 1...

Страница 10: ...at the temperature can also be measured when the valve is inactive 2 Individual probes may not be used for several controllers 3 Only one temperature probe may be used at the terminals 4 All probes bi...

Страница 11: ...m temperature controller 2 Program the desired functions 3 Check all functions 4 Install all removed parts 5 Familiarise the operator with the functions Electrical drawings Legend BC Bimetallic thermo...

Страница 12: ...system example Technical modifications reserved Information provided without guarantee Customer specific modification possible KWD EC RR 22 0 Enabling contact CF SA BC SM Bimetallic thermostat alterna...

Страница 13: ...ture probe Inlet temperature probe JP4 B RR 22 0 and SR 1 with multiple KWD EC two wire system example Technical modifications reserved Information provided without guarantee Customer specific modific...

Страница 14: ...nical modifications reserved Information provided without guarantee Customer specific modification possible WLT S RR 22 0 Enabling contact CF SA BC SM Bimetallic thermostat alternative Room temperatur...

Страница 15: ...reserved Information provided without guarantee Customer specific modification possible RR 22 0 Enabling contact SA BC SM Bimetallic thermostat alternative Room temperature probe Inlet temperature pr...

Страница 16: ...cal modifications reserved Information provided without guarantee Customer specific modification possible KWK RR 22 0 Enabling contact CF SA BC SM Bimetallic thermostat alternative Room temperature pr...

Страница 17: ...eserved Information provided without guarantee Customer specific modification possible RR 22 0 Enabling contact SA BC SM Bimetallic thermostat alternative Room temperature probe Inlet temperature prob...

Страница 18: ...rovided without guarantee Customer specific modification possible Electrical wiring diagram four wire system DKT 4 RR 22 0 Enabling contact CF SA BC SM Bimetallic thermostat alternative Room temperatu...

Страница 19: ...ons reserved Information provided without guarantee Customer specific modification possible RR 22 0 Enabling contact CF SA BC SM Bimetallic thermostat alternative Room temperature probe Inlet temperat...

Страница 20: ...EMKO GmbH Co KG Air conditioning and heating technology Im Seelenkamp 12 D 32791 Lage Postfach 1827 D 32777 Lage Telephone 49 5232 606 0 Fax 49 5232 606 260 E mail info remko de Website www remko de W...

Отзывы: