5
Close all the bottle valves.
Let flame burn out.
The fan should still run for a few se-
conds to exhaust the accumulated
heat.
Putting out of Service
Put operating switch into “0” position (=
off) and unplug mains plug from the
mains socket.
Hint PGT 100
The unit has been equipped with
an automatic fan af-
ter-running phase
to avoid heat accumulation and
consequently the release of STB when the burner has
been switched off.
Therefore the electric connection to the mains may not
be interrupted (with the exception of emergency situa-
tions) before the post-cooling time has lapsed!
Put operating switch into “II” position. In this
position only the ingoing air fan runs and the
unit can be used for air circulation.
Ventilation
Important!
Make sure to place gas reservoir only laterally behind
the unit! Never heat up or defrost gas reservoir through
the unit’s hot air current (
danger of explosion!
).
Never use gas reservoir in a lying position when the unit
is operating (gas leakage in the liquid phase).
Important Hints
Assembly of Multi-bottle Set
To avoid intensive icing of the gas bottle during a longer
operation of the unit, we recommend that you use a
bottle battery consisting of at least 3 bottles. All bottle
valves must be open to ensure regular gas supply!
T-connection
high pressure hose 0.4 m
pressure controller
hose-break protection
gas hose to unit
When the fault-indicating lamp of
the automatic burner relay is lit
up, the reason for the fault has to
be detected and to be eliminated
first.
Release is carried out by pressing
the fault-button.
It is not possible to unlock the automatic burner relay
immediately after releasing.
M a k e s u r e t o o b s e r v e w a i t i n g t i m e o f a p p r ox .
6 0 s e c o n d s !
You will find a detailed chart for the fault
elimination in chapter “Action in the case of faults”.
2. Automatic Burner Relay
“RESETTING” is not possible before the sensor has
cooled down below approx. 90 °C.
Fault Elimination Hints
1. Safety Temperature Limiter
The safety temperature limiter (STB) interrupts gas
supply in the case of overheating and the unit is locked
on the electric side. Any unit function is switched off.
When the safety temperature limiter has released, the
reason for the fault is to be detected and to be elimina-
ted first. Unlocking is carried out when the protective
cap has been unscrewed by pressing the key “STB-
RESET“.
- remove protective cap (1)
- press key (2)
- refit protective cap (1)
Clean gas supply line thoroughly before starting the unit for the first time!
G
G
1
2
F