REMKO MVT 1050 DC Скачать руководство пользователя страница 26

REMKO MVT

26

Technical data

MVT 600 DC

MVT 900 DC

MVT 950 DC MVT 1050 DC

Operating mode

Inverter multisplit outdoor units for cooling and heating

Nominal cooling output 

1)

 

kW

5,22

b)

 (1,66

a)

-7,77

c)

) 7,80

d)

 (1,66

a)

-9,86

e)

)  7,91

f)

 (1,61

a)

-11,09

g)

) 10,56

h)

 (1,66

a)

-14,59

i)

)

Nominal heating output

2)

 

kW

6,10

b)

 (1,72

a)

-7,84

c)

) 8,75

d)

 (1,72

a)

-11,65

e)

) 8,79

f)

 (1,85

a)

-12,30

g)

) 11,10

h)

 (1,86

a)

-16,03

i)

)

Working range of outdoor unit, cooling

°C

-7 to +48

Working range of outdoor unit, heating

°C

-7 to +34

Refrigerant

R 410A 

4)

Energy efficiency class, cooling 

1)

 

b)

d)

f)

h)

Energy efficiency ratio EER

1)

3,24 

b)

3,25 

d)

3,22 

f)

3,06 

h)

Energy efficiency class, heating 

2)

 

b)

d)

f)

h)

Coefficient of performance COP 

 2)

3,65 

b)

3,62 

d)

3,60 

f)

3,28 

h)

(500h) K /H

770 

b)

 / 835 

b)

1145 

d)

 / 1210 

d)

1290 

f)

 / 1410 

f)

1725 

h)

 / 1690 

h)

Max. operating pressure

kPa

4200

Air flow rate, max.

m³/h

2500

3000

5800

Noise output max. 

3)

dB(A)

49

58

60

61

Voltage supply

V/Hz

230V/1~/50Hz

Protection degree

IP

24

Nom. electrical power consumption, cooling 

1)

kW

1,61 (0,64-2,15)

2,40 (0,65-3,08)

2,46 (0,76-3,09)

3,45 (0,80-4,68)

Electr. nominal power consumption cooling 

1)

A

7,84 (3,20-9,50)

11,39 (3,31-14,50)

11,76 (3,73-15,15)

15,50 (3,81-20,75)

Nom. electrical power consumption, heating 

2)

kW

1,67 (0,62-2,07)

2,42 (0,63-3,02)

2,44 (0,85-3,22)

3,38 (0,82-4,81)

Electr. nominal power consumption heating  

2)

A

7,92 (3,02-9,78)

12,09 (3,11-14,13)

12,26 (3,57-14,86)

15,21 (4,08-21,24)

Electr. nominal power consumption compressor

A

9,70

9,80

10,80

13,50

Electr. starting current, max.

A

35

35

40

67

Electrical power consumption, max.

kW

3,10

4,00

4,80

6,30

Compressor model

Rotary piston

Twin pistons

Flow regulator

Electronic expansion valves

Refrigerant, basic quantity

kg

2,15

2,25

2,55

2,70

Refrigerant, additional quantity > 5m

g/m

30

30

30

30

Quantity of indoor units

2

3

4

4

Refrigerant connection, injection pipe

Inches 

(mm)

1/4 (6.35)

1/4 (6.35)

1/4 (6.35)

1/4 (6.35)

Refrigerant connection suction pipe IU(2,00 kW)

Inches 

(mm)

3/8 (9.52)

3/8 (9.52)

3/8 (9.52)

3/8 (9.52)

Refrigerant connection suction pipe IU(2,60 kW)

Inches 

(mm)

3/8 (9.52)

3/8 (9.52)

3/8 (9.52)

3/8 (9.52)

Refrigerant connection suction pipe IU(3,5 kW)

Inches 

(mm)

1/2 (12.70)

1/2 (12.70)

1/2 (12.70)

1/2 (12.70)

Refrigerant connection suction pipe IU(5,2 kW)

Inches 

(mm)

1/2 (12.70)

1/2 (12.70)

1/2 (12.70)

1/2 (12.70)

Refrigerant pipe, max. length per indoor unit

m

20

Refrigerant pipe, max. height per indoor unit

m

10

Refrigerant pipe total, max. 

m

30

45

60

70

Dimensions Height

mm

680

680

835

966

Width

mm

845

845

900

990

Depth

mm

315

315

305

396

Weight

kg

71

72

80

86

Serial number

 783...

 784...

785...

1042...

Computerised part no.

1623300

1623310

1623320

1623330

1) Outdoor temperature TK 35°C / FK 24°C, max. air flow rate, 5m pipe length in combination with MXW
2) Outdoor temperature TK 7°C / FK 6°C, max. air flow rate, 5m pipe length in combination with MXW

   3) Gap 1 m free space                                           4) Contains greenhouse gas according to Kyoto protocol
 

IU = Indoor unit
In combination with 

a) 1 x MXW 200 

 

b) 2 x MXW 260 

c) 1 x MXW 200, 1 x MXW 260    d) 3 x MXW 260 

 

 

e) 2 x MXW 200, 1 x MXW 520 

f)  4 x MXW 200 

g) 3 x MXW 200, 1 x MXW 520 

h) 4 x MXW 260 

 

 

i)  2 x MXW 200, 2 x MXW 520 

Содержание MVT 1050 DC

Страница 1: ...Edition GB C01 REMKO MVT MVT 600 DC MVT 900 DC MVT 950 DC MVT 1050 DC Inverter multisplit outdoor units Operation Technology Spare parts...

Страница 2: ......

Страница 3: ...ycling 4 Warranty 4 Intended use 5 Transport and packaging 5 Description of the equipment 5 6 Combinations 7 8 Operation 9 Shutdown 9 Care and maintenance 9 Troubleshooting and customer service 10 11...

Страница 4: ...ould only be set up and installed by qualified personnel The setup connection and operation of the unit and its components must be in accordance with the operating conditions stipulated in this manual...

Страница 5: ...n valves and a liquefier fan The outdoor unit is combinable with REMKO indoor units of series MXW in accordance with the cooling output see chapter Combinations The outdoor unit refrigerant circuit is...

Страница 6: ...System design The connection between indoor units A B C D and outdoor units connection circuit A B C D of the outdoor unit is achieved with refrigerant pipes and a control line Injection pipe Suction...

Страница 7: ...s Combination 13 Combination 14 Combination 15 Combination 16 Combination 17 Combination 18 Combination 19 Combination 20 Combination 21 Combination 22 MXW MXD MXT 200 201260 261350 351520 521 One ind...

Страница 8: ...1 MXW MXD MXT 200 260 350 520 One indoor unit Combination 1 Combination 2 Combination 3 Combination 4 Two indoor units Combination 5 Combination 6 Combination 7 Combination 8 Combination 9 Combination...

Страница 9: ...tenance It is recommended that maintenance contract with annual maintenance interval with an appropriate specialist company This ensures the operational reliability of your equipment TIP The compresso...

Страница 10: ...on the outdoor unit running Fan winter controller should be checked Leaking refrigerant circuit Are there signs of severe frost on the large stop valve Repair by a specialist Fault Possible cause Chec...

Страница 11: ...between outdoor and indoor unit Contact specialist dealer P0 Excessive temperature Klixon compressor Check refrigerant Check the resistance of the compressor sensor normal 0 P1 High pressure sensor ha...

Страница 12: ...basic length of the refrigerant pipe exceeds 5 metres For the quantity of additional refrigerant refer to chapter Add refrigerant Only use the union nuts for the refrigerant pipes included in the del...

Страница 13: ...d by the measures Wind If the unit is being installed in windy areas ensure the air discharges in the prevailing wind direction If this is not the case it may be necessary to install a windbreak provi...

Страница 14: ...s and potential cracking are the consequences Minimum clearances Oil return measures Outdoor unit Oil pump bend in suction pipe to outdoor unit 1 x every 2 5 metres of rising pipe Radius min 50 mm max...

Страница 15: ...mentary information for Installation When combining the outdoor unit with indoor unit MXW 350 the connection of the refrigerant pipes differs In this case install the expansion fittings to the outdoor...

Страница 16: ...completely extracted from the system the valves on the pressure gauge station are closed and the valves on the outdoor unit are opened as described in the chapter on Commissioning All electrical inst...

Страница 17: ...Suction pipe A A B B C C Control board Control board Trans former Trans former Trans former Trans former Sensor Sensor Sensor suction pipe Sensor suction pipe Heating Heating Fan motor Fan motor Power...

Страница 18: ...ve A B C D Compressor Line filter C B A D Indoor units Heating Fan motor Power output 230V 1 50Hz Inverter valve Power board Sensor Suction pipe High pressure switch Low pressure switch Sensor MVT 105...

Страница 19: ...ns cable 230 V 1 50 Hz L1 N PE N L N L1 MVT 900 DC Indoor unit Circuit A Plug Outdoor unit Circuit A Indoor unit Circuit B Indoor unit Circuit C Plug Outdoor unit Circuit B Plug Outdoor unit Circuit C...

Страница 20: ...a basic quantity of refrigerant In addition an additional amount of refrigerant must be added for refrigerant pipe lengths exceeding 5 meters per circuit Refer to the following chart Note that the emp...

Страница 21: ...pen the stop valves by turning them anti clockwise using a spanner If leaks were found draw off the refrigerant and rework the defective connection It is imperative that the vacuum creation and drying...

Страница 22: ...sensor liquefier Temperature sensor air inlet Liquefier Temperature sensor hot gas Power consumption compressor Degree of opening for electronic Expansion valve no 4 Degree of opening for electronic e...

Страница 23: ...45 C 12 45 50 C 13 50 55 C 14 55 60 C 15 60 65 C 16 65 70 C Display Temperature 15 7 5 C 20 5 0 C 25 2 5 C 30 0 C 35 2 5 C 40 5 0 C 45 7 5 C 50 10 0 C 55 12 5 C 60 15 0 C 65 17 5 C 70 20 0 C 75 22 5...

Страница 24: ...ensions and constructional design as part of the ongoing technical development process Unit dimensions All values in mm MVT 600 DC MVT 900 DC MVT 950 DC 560 335 705 315 845 595 335 860 305 900 MVT 105...

Страница 25: ...r compressor 111103 111033 111053 9 Condenser liquefier fan 111104 111034 111109 111081 10 Stop valve suction pipe 111035 111036 111055 111082 11 Stop valve injection pipe 111037 111038 111056 111083...

Страница 26: ...0 10 80 13 50 Electr starting current max A 35 35 40 67 Electrical power consumption max kW 3 10 4 00 4 80 6 30 Compressor model Rotary piston Twin pistons Flow regulator Electronic expansion valves R...

Страница 27: ...VT 1050 DC Kombination mit 4 x MXW 260 0 00 2 00 4 00 6 00 8 00 10 00 12 00 14 00 16 00 18 00 24 12 7 4 0 5 7 15 Au entemperatur C Heizleistung kW Reihe MVT 1050 DC Characteristic curves heat Heating...

Страница 28: ...mentation Inverter multisplit outdoor units Series Designation REMKO MVT 600 DC MVT 900 DC MVT 950 DC MVT 1050 DC Series Class Number 783 784 785 1042 Applicable regulations MA RL 2006 42 EC Machine d...

Страница 29: ...Notizen...

Страница 30: ...REMKO MVT 30...

Страница 31: ......

Страница 32: ...salesmen above all they must advise our clients in the areas of air conditioning and heating technology Customer Service Our equipment is precise and reliable However should a fault should occur REMKO...

Отзывы: