The ML 261-681 air conditioning
equipment consists of an REMKO
ML...AT outdoor component and
an ML...IT interior unit.
The outdoor component serves to
output the heat extracted by the
interior unit from the room being
cooled.
In heating mode, the interior unit
dissipates the heat extracted by
the outdoor component.
The outdoor component can be
installed outdoors or indoors. The
latter requires the fulfilment of
certain conditions. The indoor unit
is designed for interior use and
should be mounted high up on a
wall. It is operated by an infrared
remote control.
The outdoor component comprises
a refrigerant and compressor,
liquefier with fins, liquefier
fan, reverse flow fan and flow
regulator. The outdoor component
is controlled by the regulator in the
indoor unit.
The indoor unit comprises a finned
vaporiser, vaporiser fan, controller
and condensation tray.
Winter controllers, floor and wall
brackets, refrigerant pipes and
condensation pumps are also
available as accessories.
Description of the
equipment
The equipment was shipped in
sturdy packaging. Immediately
check the equipment on delivery
and make a note of any damage or
missing parts on the delivery note.
Inform the forwarding agent and
contractual partner.
Warranty claims at a later date will
not be accepted.
Transportation and
packaging
Schematic of refrigerant circuit in indoor unit
Vaporiser fan
Connection to
suction pipe
Connection to injection pipe
Vaporiser
Refrigerant pipes are used to connect the indoor unit to the outdoor
component.
Outdoor
component
System layout
Injection pipe
Indoor unit
Indoor area
Outdoor area
Stop valve
Liquefier fan
Condensation pipe
Suction pipe
Condensation pipe
Control cable
Mains cable
M
M
Schematic of exterior refrigerant circuit
Liquefier fan
Connection valve
Suction pipe
Connection valve
Injection pipe
Compressor
Capillary tube flow regulator
Filter dryer
Liquefier
Reverse flow valve
Connection for
pressure gauge
5