5. Recirculation mode:

In this mode, the unit is used as an air circulation

unit. It is not possible to set a target temperature.

The room is neither heated nor cooled. Please

always observe the following additional informa-

tion: This mode allows the heat trapped under the

ceiling to be circulated to the lower regions of the

room in winter.

8

 

Follow me/filter cleaning

Pressing this key activates the "Follow Me" func-

tion. In this mode, the temperature is measured at

the remote control and the actual temperature is

displayed on the remote control.

9

Fan stage

Press this key to set the fan speed. A selection can

be made between low, medium, high and auto-

matic fan speed. In automatic mode, the word

“Auto” flashes.

10

 

Infra-red remote control signal receiver

Setting the time

Press and hold the “Timer” key for 3 sec. to access

the setting mode. The number of hours now

flashes and can be altered with the keys 

 and

.

By pressing the 

 and 

 keys you can move

the minutes setting. You can alter the number of

minutes by pressing the 

 and 

 keys again.

To confirm the entries, press the 

 key or wait 5

seconds.

Locking the wired remote control

The symbol 

 appears on the display when you

press the 

 and 

 keys simultaneously. The

wired remote control is now locked and is unre-

sponsive when keys are pressed. The device no

longer receives signals from the infra-red remote

control in this locked mode.

To unlock the remote control, press the 

 and

 keys simultaneously. The 

 symbol disap-

pears.

Cleaning the filter

The wired remote control has a reminder function

which reminds you to clean the filter. The remote

control records the number of operating hours your

air conditioning unit has reached. The 

 symbol

appears on the display after 2500 operating hours.

Please clean the filter and reset the display by

holding down the 

 key.

Assembly instructions

for qualified personnel

Check the contents of the packaging for complete-

ness and check the unit for visible transport

damage. Immediately notify your contract partner

of any deficiencies.

 NOTICE!

Installation should only be performed by author-

ised specialists.

 DANGER!

All electrical installation work is to be performed

by specialist companies. Disconnect the power

supply when connecting the electrical terminals.

 

Check all plugged and clamped terminals to

verify that they are seated correctly and make

permanent contact. Tighten as required.

Fig. 3: Removing the housing cover

 

 

 

 

 

9

Содержание KFB 3

Страница 1: ...Assembly and operating instructions Read the instructions prior to performing any task REMKO KFB 3 Wired remote control RVD DC RVT DC RXT DC MXD MXT MVD and MVW 0061 2013 09 Edition 1 en_GB...

Страница 2: ...g inal Read these operating instructions carefully before commis sioning using this device These instructions are an integral part of the system and must always be kept near or on the device Subject t...

Страница 3: ...es for installation maintenance and inspection 5 1 8 Unauthorised modification and changes 5 1 9 Intended use 5 1 10 Warranty 5 1 11 Transport and packaging 6 1 12 Environmental protection and recycli...

Страница 4: ...y be fatal or cause serious injury WARNING This combination of symbol and signal word warns of a potentially hazardous situation which if not avoided may be fatal or cause serious injury CAUTION This...

Страница 5: ...ly be secured or mounted on stable structures walls or floors n Mobile units must be set up securely on suit able surfaces and in an upright position Sta tionary units must be permanently installed fo...

Страница 6: ...on and recycling Disposal of packaging All products are packed for transport in environ mentally friendly materials Make a valuable contri bution to reducing waste and sustaining raw mate rials Only d...

Страница 7: ...mensions height width depth mm 120 120 20 Weight kg 0 2 Max cable length m 15 Recommended cable mm2 4 x 0 5 We reserve the right to modify the dimensions and design as part of the ongoing technical de...

Страница 8: ...ure is 1 C above the desired temperature and sufficient coolant is available the indoor unit will start to cool the room air If the actual temperature falls approx 0 5 C below the set room temperature...

Страница 9: ...wired remote control The symbol appears on the display when you press the and keys simultaneously The wired remote control is now locked and is unre sponsive when keys are pressed The device no longer...

Страница 10: ...d is not affected by any sources of heat or cold 5 Make the connections in accordance with the electrical circuit diagram Electric connec tions must be carried out as fixed connec tions in accordance...

Страница 11: ...D E 3 Fig 4 Electrical wiring diagram 1 Wired remote control 2 Indoor unit 3 On site extension by way of a four core cable max 15m Colour coding Wired remote control 1 A Blue B Gray C Red D Black Col...

Страница 12: ...f a single split combination with a remote control A KFB 3 B RVT 262 DC AT C RVT 262 DC IT Variant 2 Assembly of two single split combinations with a remote control e g server room A B C B C Fig 6 Ass...

Страница 13: ...Variant 3 Assembly of a multi split combination with a remote control A C C C C B Fig 7 Assembly of a multi split combination with a remote control A KFB 3 B MVT 1051 DC C MXW 262 13...

Страница 14: ...rating range 7 Operation 8 P Power supply 7 R Recirculation mode 8 Removing the housing cover 9 S Safety Dangers of failure to observe the safety notes 4 General 4 Identification of notes 4 Notes for...

Страница 15: ......

Страница 16: ...t as advisers to our customers in air conditioning and heating technology SFlbCustomer Service Our equipment operates precisely and reliably However in the event of a fault REMKO customer service is q...

Отзывы: