1
On/off key:
After actuating the ON/OFF key whilst switched off,
the unit starts as soon as the humidity in the room
(RH) is above the target value set for the humidity
in the room.
The start sequence is:
Fan motor starts slowly, after approx. 2 minutes the
compressor switches on. The compressor is at full
power after about 1 1/2 minutes. During operation,
the control indicator [8] lights up on the display.
If the ON/OFF key is actuated during operation,
the unit and the control indicator [8] switch off. Fan
and compressor shut down in approx. 1 minute.
2
Silent mode:
By pressing the Silent key, the unit can be set to
Silent mode, whereby the compressor and fan only
operate at a maximum of 80% of their power. This
reduces the maximum unit volume.
The power level indicator [7] on the display shows
which mode the unit is in (2 bars = silent mode, 3
bars = standard mode).
The display switches itself into a stand-by state
(dimmed display brightness) after a few sec-
onds. Pressing any key reactivates the display
(full display brightness). Only the second press
of a key carries out the action.
3
Timer:
The unit can be switched on or off with a delay via
the timer. The timer indicator [10] and the hour
indicator [9] are required for setting.
The timer indicator shows whether it is a switch-on
delay (1) or a switch-off delay (0). The timer can be
set both when the unit is switched on and when it
is switched off.
By pressing the timer key, 1 appears on the timer
display and the hours on the hour display [9] flash.
Use the arrow key to set the number of hours (0-23
hours). These are confirmed by pressing the timer
key. Then the minutes (0-60 minutes) can be set
and confirmed by pressing the timer key. Then the
0 appears on the timer indicator. The switch-off
delay is set in the same way as the switch-on
delay (first hours, then minutes).
After setting the times, the respective symbol 1 or
0 lights up on the timer indicator [10]. A timer is
only set if the time (hours:minutes) is changed; if
the time is not changed, this time (0 or 1) is consid-
ered deactivated. The timer is only one time for
both the switch-on and switch-off delay. After suc-
cessfully switching the unit on or off, the timer is
deactivated.
4
Desired humidity setting:
After the unit is switched on, the target room
humidity can be adjusted up or down by pressing
the arrow keys. As soon as the room humidity rea-
ches the target humidity set, the compressor and
the fan motor stop. The target room humidity set is
displayed for 3 seconds during the adjustment and
then reverts to the current measured room
humidity.
NOTE:
n
If the unit is restarted it reverts to the pre-
vious setting
n
The adjustment steps for the target humidity
are 1% ( RH) per key press. The adjustment
range for the target humidity should lie
between 30% and 95% ( RH)
If the room humidity is below the set target room
humidity, the compressor and the fan motor stop. If
the room humidity is higher than the set target
room humidity, the unit restarts with a 3-minute
delay.
5
Humidity indicator:
The standard display is the current measured room
humidity. The humidity value to be changed is dis-
played for 3 seconds by pressing one of the arrow
keys [4] to set the target room humidity.