The units are designed exclusively 
for drying and dehumidification 
purposes in industrial or 
commercial situations on the basis 
of their structural design and 
equipment. 

The units must only be operated 
by appropriately instructed 
personnel. 

A failure to observe 
the manufacturer's specifications, 
the respective local legal 
requirements or arbitrary 
alterations to the units, exempts 
the manufacturer from liability 
for resulting damage.

Customer service 
and guarantee

As a prerequisite for any guarantee 
claims to be considered, it is 
essential that the ordering party 
or its representative complete 
and return the 

“Certificate of 

guarantee”

 to REMKO GmbH & 

Co. KG at the time when the units 
are purchased and commissioned. 

The units have been tested several 
times in the factory to verify their 
correct function.  
However, if malfunctions should 
arise that cannot be remedied by 
the operator with the assistance of 
the troubleshooting section, please 
contact your specialist dealer or 
contractual partner.

Intended use

Environmental 

protection and 

recycling

Disposal of packaging

When disposing of packaging 
material, please consider our 
environment. 
Our units are carefully packed 
and delivered in stable transport 
packaging and, if applicable, 
on a wooden pallet.  
The packaging materials are 
environmentally-friendly and can 
be recycled.
By recycling packaging materials, 
you make a valuable contribution 
to the reduction of waste and 
conservation of raw materials.

Therefore, only dispose of 
packaging material at appropriate 
collection points.

Disposal of the old unit

 

The manufacturing process for 
the units is subject to continuous 
quality control. 
Only high-grade materials are 
processed, the majority of which 
are recyclable.

You also contribute to 
environmental protection by 
ensuring that your old equipment 
is only disposed of in an 
environment friendly manner.

Therefore, only bring the old 
unit to an authorised recycling 
business or to an appropriate 
collection point

.

NOTE

Operation that differs from 
that specified in this operating 
manual is prohibited.
Failing to observe this renders 
any manufacturer liability 
or guarantee claims void.

NOTE

Adjustment and maintenance 
work may only be carried out  
by authorised and qualified 
technicians.

Important information 
concerning recycling

The units are operated with 
environmentally-friendly and 
ozone-neutral R290 refrigerant.
The mixture of refrigerant and oil 
within the unit must be disposed 
of properly in accordance with 
the statutory or locally-applicable 
regulations.

CAUTION

Copyright

The redistribution, even 

in part, or the use of this 

documentation for purposes 

other than intended is 

strictly prohibited without 

the written authorisation of 

REMKO GmbH & Co. KG

.

13

Содержание ETF 500 Eco

Страница 1: ...Operating and installation instructions Edition EN X02 Read the instructions prior to performing any task ETF 500 Eco ETF 600 Eco REMKO ETF Eco series Mobile air dehumidifiers...

Страница 2: ......

Страница 3: ...to modifications No liability accepted for errors or misprints Air dehumidification 4 6 Safety notes 6 12 Intended use 13 Customer service and guarantee 13 Environmental protection and recycling 13 Un...

Страница 4: ...leased from parts of a building or materials is absorbed by the surrounding air As a result the moisture content increases which ultimately gives rise to corrosion mould rot peeling of paint and other...

Страница 5: ...condenses and is collected in a condensate trap from where it is drained off Drying materials Water vapour condensation Because the capacity for the maximum possible volume of water vapour increases a...

Страница 6: ...s its moisture Safety notes General safety notes Carefully read the manual before commissioning the units or their components for the first time It provides useful tips and notes such as hazard warnin...

Страница 7: ...An unobstructed air inlet and air outlet must be guaranteed at all times The air inlet grille must always be kept free of dirt and loose objects The units must not be covered during operation The unit...

Страница 8: ...close to the unit For safety reasons people with mental physical or other health limitations must not operate this unit unattended The unit is not permitted to be operated with damaged cables The unit...

Страница 9: ...t all times Work may only be car ried out by authorised specialist personnel with knowledge of handling combustible refriger ants Prepare the work area Any persons present must be informed about the r...

Страница 10: ...e guaranteed again If the defect on the spare part cannot be remedied and downtime of the unit is no longer acceptable an adequate temporary solution must be arranged The owner operator of the unit mu...

Страница 11: ...refrigerant or if possible the affected part disconnected from the system using stopcocks The affected system parts must be flushed with oxygen free nitrogen run before and during the repair work Emp...

Страница 12: ...ant Transportation of units which contain combustible refriger ants National provisions must be observed Storing of units which contain combustible refrigerant National provisions must be observed Tra...

Страница 13: ...packaging materials are environmentally friendly and can be recycled By recycling packaging materials you make a valuable contribution to the reduction of waste and conservation of raw materials Ther...

Страница 14: ...ough for rime formation to occur rendering defrosting unnecessary Therefore the air dehumidifiers work economically The cooled and dehumidified air is re heated by the condenser heat exchanger and blo...

Страница 15: ...ources of heat Air circulation is improved if the unit is set up approx 1 m above the ground The room being dried or dehumidified must be closed to the neighbouring atmosphere Avoid having opened wind...

Страница 16: ...on with a humidity switch The REMKO humidity switch accessories is supplied with a special adapter The following procedure must be followed when commissioning units in conjunction with a humidity swit...

Страница 17: ...dehumidification mode The unit will switch off and the yellow indicator light will illuminate To empty the condensate container the following procedure must be followed 1 Move the operating switch 2 t...

Страница 18: ...er 3 If moisture remains on the evaporator or water remains in the condensate container the units must only be transported in an upright position 5 Drain the condensate into a lower level drain To ope...

Страница 19: ...y be operated with the dust filter in place Observe the regular care and maintenance intervals In accordance with the operating conditions the units must if necessary be checked at least yearly by a s...

Страница 20: ...for ice or rime formation If ice has formed check the functionality of the automatic defrost and the temperature sensor Check whether or not the evaporator temperature is below room temperature If thi...

Страница 21: ...iner full H2 Control lamp green in operation K1 Time relay t 30 min M1 Compressor motor M2 Fan motor P1 Operating hours counter S1 Operating switch S2 Microswitch float S3 Defrost thermostat Y1 Defros...

Страница 22: ...imensions and design as part of the ongoing technical development process Exploded view of ETF 500 600 Eco 4 5 6 8 10 11 12 13 14 15 2 1 16 17 20 21 26 27 22 25 30 29 32 33 35 34 37 36 23 23 7 24 18 3...

Страница 23: ...Socket for time relay 16 Condenser cpl 17 Solenoid valve On request by providing 18 Defrost thermostat with probe the serial number 19 Microswitch 20 Mains cable with plug 21 Cable passage with strain...

Страница 24: ...gnature 19 Date Signature 20 Date Signature Comments Unit type Unit number 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 Unit cleaned outside Unit cleaned inside Fan blade cleaned Fan housing cle...

Страница 25: ...0 Max rated current consumption A 2 71 2 90 Max power consumption kW 0 62 0 67 At 20 C 70 RH kW 0 49 0 50 Specific energy consumpt SEC max kWh l 0 31 0 26 At 20 C 70 RH kWh l 0 26 0 20 Electrical prot...

Страница 26: ...26 REMKO ETF Eco Series...

Страница 27: ...27...

Страница 28: ...5232 606 260 E mail info remko de URL www remko de REMKO GmbH Co KG Klima und W rmetechnik Im Seelenkamp 12 32791 Lage Hotline within Germany 49 0 5232 606 0 Hotline International 49 0 5232 606 130 W...

Отзывы: