8
Starting
A humidity of 45% to 60% is sufficient for residential
rooms; a humidity of 40% to 45% should not be ex-
ceeded in storage rooms, archives, etc.
Regulation with Hygrostat
The integrated hygrostat controls the switching functions
for automatic operation.
Starting the unit
After moving the unit, wait at least five minutes
before starting it to prevent damage to the com-
pressor.
G
Insert the power plug into a cor-
rectly fused plug socket.
230V/1~ 50 Hz / 10 A fuse.
Ensure that the plug S is correctly
installed in the hose connector on
the rear of the unit.
S
Turn the knob on the operating
panel counterclockwise to the
“OFF” position.
Select the required humidity with
the hygrostat.
Approximate values:
CONT.
ð
20 % r. F.
OFF
ð
80 % r. F.
white area
ð
40 % r. F.
Installation
◊
Install the unit in a horizontal position to ensure the
trouble-free drainage of condensate.
◊
Install the unit in the middle of the room, if possible,
to ensure optimal air circulation.
◊
If this is not possible due to the on-site situation,
please ensure that the air can be drawn into the front
of the unit and exhausted at the back or the top air
control flap without obstructions.
◊
Make sure to observe a minimum distance of 50 cm
◊
Do not install the unit directly near radiators
or other heat sources.
◊
Make sure to keep the room to be dried and
dehumidified closed, so that air from outside cannot
penetrate into it.
◊
Entering into and going out of the room should be
avoided if possible.
◊
You can obtain better air circulation if you place the
unit at a height of approx. 1 m.
Important Hints!
◊
Make sure that appropriate measures for mainte-
nance and care are taken when the unit is installed
in dusty surroundings as well as in stables with am-
moniacal atmosphere
See chapter “Maintenance and Care”.
◊
The electrical connection of the unit is to be carried
out according to DIN VDE 0100, part 704. It is to be
connected to service entrances with residual current
operated device.
◊
If the unit is installed in washhouses, showers or
similar wet areas the user has to protect it by an ade-
quate residual current operated device according to
the relevant regulations.
G
The filter of the unit is to be controlled and
cleaned thoroughly before every use. If the air
suction grille is dirty, please cleaned it up like
shown in chapter ”Maintenance and Service”.
Important Hints:
◊
Connection cable extensions may only be used
when they have been completely unrolled.
◊
If the condensat tank is not fitted correctly, the unit
will not run.
minimum distance of 0,5 m
Please keep distance to the
radiator or other heating sources
keep the
window
closed
keep the
door
closed