REMKO Easy-Control EC1 Скачать руководство пользователя страница 9

Operation

Remote control display

6

1

2

4

5

8

7

3

9

Fig. 3: Remote control display

The remote control display is realised through the

corresponding symbols on the touch display.

1

 

Days of the week

2

 

Setpoint

Is displayed if the room temperature is set.

3

 

Room temperature

Is displayed if the room temperature is displayed.

4

 

Automatic mode, time program active

In this case, no time programs of the Smart-Control

Touch are active.

5

 

Manual mode, no time program

6

 

Heating/cooling

7

 

Present or absent

It is possible to enter up to 6 heating times per day.

8

 

Room set/actual temperature

9

 

Time

Keys for the remote control settings

10

11

12

13

14

Fig. 4: Keys on the remote control

The remote control is operated using the relevant

keys on the touch display.

10

 

“On / off” key

Activation of the room temperature regulation. If

the display is switched off, anti-freeze protection

mode is active

11

 

“M” key

Switching from manual mode to present/absent

mode (time program). The following symbols

appear:

- “Manual” = manual mode

- “Clock” = time program

12

 

“Clock” key

Using this key it is possible to select and set the

hours, minutes and days of the week (1-7). To con-

firm and continue, press the “clock” key.

13

 and the 

14

 

"arrow” keys

To set the room temperature touch the “Up/down”

arrow keys [13 and 14]. The “Set” symbol is dis-

played and the set temperature is displayed. After

the setting is implemented, the display jumps from

“Set” back to the home symbol and the current

room temperature is displayed.

Key lock

To prevent accidental adjustment or access by

unauthorised persons, it is possible to lock the dis-

play. Press the “Clock” key [12] and the “Up arrow”

[13] at the same time for 5 seconds. If the key lock

is activated a padlock symbol appears on the right

next to the time.

 

 

 

 

 

9

Содержание Easy-Control EC1

Страница 1: ...Operating and installation instructions Read the instructions prior to performing any task REMKO remote controls EC 1 Easy Control remote control for heat pumps 0242 2019 11 Edition 1 en_GB...

Страница 2: ...rating instructions carefully before commis sioning using this device These instructions are an integral part of the system and must always be kept near or on the device Subject to modifications No li...

Страница 3: ...notes for the operator 5 1 7 Safety notes for installation maintenance and inspection 5 1 8 Unauthorised modification and changes 5 1 9 Intended use 5 1 10 Warranty 5 1 11 Transport and packaging 6 1...

Страница 4: ...fatal or cause serious injury WARNING This combination of symbol and signal word warns of a potentially hazardous situation which if not avoided may be fatal or cause serious injury CAUTION This combi...

Страница 5: ...d or mounted on stable structures walls or floors n Mobile units must be set up securely on suit able surfaces and in an upright position Sta tionary units must be permanently installed for operation...

Страница 6: ...tal protection and recycling Disposal of packaging All products are packed for transport in environ mentally friendly materials Make a valuable contri bution to reducing waste and sustaining raw mate...

Страница 7: ...temperature C 5 45 Current consumption W 1 5 Timing error 1 Housing PC ABS fire resistant Suitable flush mounted socket mm 86 x 86 square or European 60 mm round box Wire clips mm2 Wire 2 x 1 5 or 1...

Страница 8: ...sence program can also be set Using the room probe it is possible to realise room temperature guided regulation in the heating and cooling mode The installation is suitable for a standard flush mounte...

Страница 9: ...tivation of the room temperature regulation If the display is switched off anti freeze protection mode is active 11 M key Switching from manual mode to present absent mode time program The following s...

Страница 10: ...ng the time programs You have the option of storing six different time programs in the EC1 per day When doing so you can perform programming for days 1 5 Monday to Friday and day 6 Saturday as well as...

Страница 11: ...temperature Room target temperature Press 10 x Switching time 3 time Minutes Press 11 x Switching time 3 time Hours Press 12 x Switching time 3 temperature Room target temperature Press 13 x Switchin...

Страница 12: ...s 30 x Switching time 3 temperature Room target temperature Press 31 x Switching time 4 time Minutes Press 32 x Switching time 4 time Hours Press 33 x Switching time 4 temperature Room target temperat...

Страница 13: ...Hours Press 48 x Switching time 3 temperature Room target temperature Press 49 x Switching time 4 time Minutes Press 50 x Switching time 4 time Hours Press 51 x Switching time 4 temperature Room targe...

Страница 14: ...C 2 C 2 Switching hysteresis 1 C 5 C 1 C 3 Key lock 0 Key lock apart from on off 1 All keys locked 1 4 Probe type In Internal probe of the remote control Ex External probe AL Internal and external pr...

Страница 15: ...G 2 4 A D N G 3 4 A D N G 4 4 A D N G 5 4 A D N G 6 4 A D N G S S n K L C O M I M 0T1 0T1 0T2 0T2 2 B 2 A 1 B V 2 1 D N G 1 A 1 4 S 0 4 S D N G V 5 0 2 S 3 4 S 2 4 S D N G V 5 1 2 S 5 4 S 4 4 S D N G...

Страница 16: ...N G 0 4 A D N G 1 4 A D N G 2 4 A D N G 3 4 A D N G 4 4 A D N G 5 4 A D N G 6 4 A D N G S S n K L C O M I M 0T1 0T1 0T2 0T2 2 B 2 A 1 B V 2 1 D N G 1 A 1 4 S 0 4 S D N G V 5 0 2 S 3 4 S 2 4 S D N G V...

Страница 17: ...as follows 1 For installation turn the round display clock wise to release the display from the mounting plate 2 Draw the ribbon cable out of the display to avoid damage 3 Connect the power supply to...

Страница 18: ...s to the expert level on page 14 Under point c you can assign a BUS address for your room thermostats Make sure that all components to which you assign an address are assigned different addresses If a...

Страница 19: ...the safety notes 4 General 4 Identification of notes 4 Notes for inspection 5 Notes for installation 5 Notes for maintenance 5 Personnel qualifications 4 Safety notes for the operator 5 Safety conscio...

Страница 20: ...5232 606 260 E mail info remko de URL www remko de REMKO GmbH Co KG Klima und W rmetechnik Im Seelenkamp 12 32791 Lage Hotline within Germany 49 0 5232 606 0 Hotline International 49 0 5232 606 130 W...

Отзывы: