
2
Technical data
2.1 Unit data
Series
Easy-Control EC1
Power supply
V/Hz
230 AC, 50
Current load (heating cycle pump)
A
3
Probe
NTC3950, l0K
Accuracy
°C/F
±
0.5/
±
1
Set the temperature
°C
5-35
Temperature display
°C
5-99
Ambient temperature
°C
0-45
Humidity (non-condensing)
% rel. hum.
5-95
Storage temperature
°C
5-45
Current consumption
W
< 1.5
Timing error
%
< 1
Housing
PC +ABS (fire-resistant)
Suitable flush-mounted socket
mm
86 x 86 square or European 60 mm
round box
Wire clips
mm
2
Wire 2 x 1.5 or 1 x 2.5
Enclosure class
IP30
Keys
Capacitive touch keys
We reserve the right to make technical changes for the purpose of technical advancement.
2.2 Unit dimensions
60 (±2)
86
86
50
14
14
24
50
90
50
90
A
B
C
Fig. 1: Dimensions (all measurements in mm)
A: Front view
B: Side view
C: Rear view
7